Descargar Imprimir esta página

SSS Siedle Siedle Touch 10 Informacion De Producto página 12

Ocultar thumbs Ver también para Siedle Touch 10:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
Installation
Connection system:
Connection via connecting circuit
board
In the case of surface-mounted
door stations, the connection pcb
is located behind the door loud-
speaker.
In-Home bus
2 Connection pcb for flush-
mounted door stations (shown with
SBTLM 651-... connection pcb)
3 Connection pcb for surface-
mounted door stations
4 In-Home bus wiring diagram
Notes on the wiring diagram
a) A network cable must be laid
without fail from the door station to
the distributor for configuration.
Terminal assignment
+, –
Supply voltage 48 V DC
Da, Db Data cable Vario bus
E, G
Electrically isolated input,
10–30 V DC
Evaluation via Vario bus
Terminal E = +
Terminal G = –
6, 1
Triggering Door loud-
speaker
b, c
Button illumination
12 V AC
T1, T2 Potential-free button
(system-independent, for
customer's applications, e.g.
activation of outside light)
M1, 2 Pilfer safeguard
(if available)
LAN
Network cable for
ext.
configuration
12
Access Professional
5 Connection pcb for flush-mounted
door stations (shown with SATLM
connection pcb)
6 Connection pcb for surface-
mounted door stations
7 Access wiring diagram
Notes on the wiring diagram
a) A network cable must be laid
without fail from the door station to
the distributor for configuration.
Terminal assignment
+, –
Supply voltage 48 V DC
Da, Db Data cable Vario bus
E, G
Electrically isolated input,
10–30 V DC
Evaluation via Vario bus
Terminal E = +
Terminal G = –
b, c
Button illumination
12 V AC
T1, T2 Potential-free button
(system-independent, for
customer's applications, e.g.
activation of outside light)
M1, 2 Pilfer safeguard
(if available)
LAN
Network cable for
ext.
configuration
Commissioning and
programming
Commissioning and programming
of the In-Home bus / Access
Professional are described in the
relevant system manual, which is
enclosed with the line rectifier /
server.
The Siedle Touch user interface is
configured using the configuration
software on the enclosed USB stick.
For detailed information, see the
Siedle Touch ST 10-... programming
instructions.
Servicing
The functional unit can be com-
pletely exchanged if required.
In the event of replacement, contact
Siedle service.
Before replacement, make sure
you back up the Siedle Touch data
(e.g. button layout and configura-
tion) and transfer it to the new
Siedle Touch after replacement.
Specifications
Screen diagonal: 257 mm / 10.1"
Resolution: 1280 x 800 pixels
Installation type: Horizontal or
vertical
Operating voltage: 48 V DC
Operating current: max. 500 mA
Current consumption in idle status:
350 mA
Protection system: IP 65 from the
front
Ambient temperature:
–20 °C to +55 °C
Care instructions
Clean your display carefully and only
with a soft, slightly moistened cloth.
Dry, aggressive cleaning agents and
abrasive detergents can damage the
surface!
Detailed care instructions are located
in the download area of
www.siedle.com.

Publicidad

loading