Intrinsically Safe Pressure Indicators
Introduction
These instructions detail the requirements for using the DPI 705 IS Intrinsically
Safe Pressure Indicator in a hazardous area. Read the whole publication
before starting.
ATEX Certification
Markings
Ex ia IIC T4 Ga (-10°C < Ta < +50°C) ............................hazardous location markings
BAS02ATEX1194X......................................................................................certificate number
II 1 G

1180

DPI 705 IS............................................................................................specific apparatus type
Pressure range in mbar or psi................................................ full-scale pressure rating
Druck LTD, Groby, LE6 0FH, UK.......................... manufacturer's name and address
SN*******/YY-MM.......................................................................serial number and date of
Batteries
WARNING:
Only replace batteries in a safe area.
Do not mix cell types. Use only 3 x AA LR6 manganese alkaline primary cells
from the following list:
Duracell Plus
Duracell Procell
Industrial by Duracell
Energizer Ultimate
GP Super
Installation
WARNING:
Do not use tools on the pressure indicator that might cause
incendive sparks - this can cause an explosion.
Installation should be carried out by qualified plant installation
technicians in compliance with the latest issue of EN 60079-14.
Provide additional protection for indicators that may be damaged in
service.
Special Conditions of Safe Usage
The lower ambient temperature is limited to -10°C, which is more restrictive
than the range specified in the Standard.
[EN] English
key increases the alarm value, pressing the
key to set the alarm.
...................................................... equipment group and category
.......................................................................................................CE mark
manufacture, year-month
3
K0214 Revision A