5.2
Technical data
Maximum utilisation pressure
Pump housing
Maximum suction pressure
Temperature range
Fluid temperature
Ambient temperature
Electrical data
Type of motor protection
Insulation class See rating plate
Frequency
Voltage
Power supply voltage
Types of supported power supplies
Sonstige Daten
Ambient humidity
Altitude
Noise level dB(A) 0/+3 dB(A)
Power supply cable cross section
diameter (cable equipped
with 4 wires) mm
2
- Electromagnetic compatibility
• Residential emission –
1st environment:
• Industrial interference resistance –
2nd environment:
(*) In the frequency range between 600
display or the pressure indication in the display might be
disturbed in the exceptional case of the direct vicinity
(<1 m from the electronic module) of radio transmission
installations, transmitters or similar devices working in
this frequency range. The operation of the pump is not
affected at any time.
Installation and operating instructions –
16 bar
10 bar
Notice: the actual input pressure (P input) + the pressure at zero delivery
rate (P zero delivery rate) must always be lower than the maximum
authorised operating pressure (Pmax). If the maximum authorised
operating pressure is exceeded, the mechanical seal and the roller
bearing can be damaged or their life span reduced.
P input + P zero delivery rate ≤ Pmax
Refer to the pump plate for the maximum operating pressure: Pmax
-15 °C to +50 °C
-15 °C to +40 °C (other temperatures on request)
See motor plate
1.1
TN, TT
< 90 % without condensation
< 1000 m (> 1000 m on request)
≤ 55 dB(A)
1.1
1.5 - 2.5
(*)
PN-EN 61800-3
PN-EN 61800-3
MHz and 1
GHz, the
Wilo-Multivert MVISE 3G
Power (kW)
2
400 V (±10%) 50 Hz
380 V (±10%) 60 Hz
480 V (±10%) 60 Hz
Power (kW)
2
2.5 - 4
- Outline and connection dimensions (Fig. 3).
5.3 Scope of delivery
• High-pressure multistage centrifugal pump
• 2 oval flanges (counter flanges) with female
thread, gaskets and screws
• Installation and operating instructions
English
41