Step 11: (fig. 11)
Move the flow control lever (2) as far as it will go to the
"OFF" position. Push the feed plate back as far as it will go to
the closed position. See figure 11.
Place the bent end of the flow control link (44) into the feed
plate bracket and a 1/4" flat washer (37). Secure it with a
3/32" x 3/4" cotter pin (24). See figure 11.
Tighten the lower 1/4" nylock hex nut (26) until it touches
the bottom of the ferrule, then tighten the upper 1/4"
nylock hex nut (26) until it is snug against the top of the
ferrule. See figure 11.
Open and close the feed plate using the flow control lever.
Check to make sure the feed plate is closed completely
when the lever is in the "OFF" position. If the feed plate does
not close completely, adjust the 1/4" nylock hex nuts (26) on
the flow control link (44). See figure 11.
Fig. 11
26
26
44
FEED PLATE
6
2
24
37
Step 12: (fig. 12)
1. Push a flanged bearing (22) into each side of the drive
disk (8). See figure 12.
Fig. 12
8
22
Step 13: (fig. 13)
1. Push a flanged bearing (22) into each of the eight spike
disks (7), from the side shown in figure 13.
7
Fig. 13
Step 14: (fig. 14)
1. Press flanged bearings (22) into both of the end plates.
See figure 14.
2. Place the 1/4" thick spacer (40) onto the spike disk
shaft (12) and then insert the shaft through the flanged
bearing (22) in the left hand end plate. See figure 14.
Fig. 14
22
22
22
22
40
12