Saivod ASG0920WI Manual Del Usuario página 210

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note:
● Never cut the power connection wire to prolong or shorten the distance.
Step six: neaten the pipes
1. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is 10cm.
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in
order to prevent rain from getting into the
room.
Note:
● The through-wall height of drain hose
shouldn't be higher than the outlet
pipe hole of indoor unit.
● The water outlet can't be placed
in water in order to drain smoothly.
The water outlet
can't be placed
in water
the drain hose
can't raise
upwards.
U-shaped curve
● Slant the drain hose slightly dow-
nwards. The drain hose can't be
The drain hose can't be fluctuant
The drain hose
can't be fluctuant
wall
drain hose
The water
outlet can't be
fluctuant

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido