SETTING THE TIMER

The Delay ON-Timer and Delay OFF-Timer cannot be
selected simultaneously.
• Press the Timer Selection Button 1.
• Select one of the following five types of operation.
Each time the button is pressed, the operation mode
is shifted in the arrow direction.
Delay OFF Timer
H
OFF
Delay ON Timer
H
ON
Delay OFF and
ON Timer
H
H
OFF
ON
Delay ON and
OFF Timer
H
H
ON
OFF
• Then press the Timer Setting Button 2 or 3 to the
desired number of hours.
(Number of hours which can be set : 1 ~ 12)
• Press the Timer Set/Cancel Button 4
7

CONVENIENCE OPERATION

I Sleep Mode Operation

To obtain a comfortable room temperature while
sleeping:-
• Press 5.
• Sleep mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
G Sleep Mode Operation Details
• When the room temperature reaches the set
temperature, the airflow volume will change to low
automatically.
• Sleep Mode Operation time is 5 hours.
• When used together with the timer, the timer has a
priority.
Temperature
Example :
Operation Stops
S
T
after 1 hour
e
e
m
ON Timer.
t
p
t
e
i
r
n
a
g
t
Example :
u
r
Operation starts after
e
6 hours.
Example :
Temperature
Operation stops after
1 hour and re-starts
S
T
after another 5 hours.
e
e
m
t
p
t
e
i
r
n
Example :
a
g
t
Operation starts after
u
10 hours, and then
r
Sleep
e
stops after another 8
Operation
hours.
button is
pressed.
0~1 hour
Cooling Model
When the room temperature
become a level ideal for
sleep, the operation 10
minutes on and 20 minutes
off will be repeated.
Approx. 1°C
increase.
Approx.
1°C
increase.
• Cooling or Soft Dry
Sleep
Operation for sleep shift
Operation
operation will start to
Sleep shift
button is
avoid overcooling.
operation
pressed.
starts.
← 1 hour →
0~1 hour
after approx. 5 hours of sleep shift
operation, it will stop automatically.
Heat Pump Model
Approx. 1°C
increase.
Approx.
1°C
increase.
• Cooling or Soft Dry
Operation for sleep shift
operation will start to
avoid overcooling.
Sleep shift
operation starts.
• Heating operation for
sleep shift operation will
start to avoid overheating.
Approx. 2°C
← 1 hour →
decrease.
Approx. 3°C
← 1 hour →
decrease.
after approx. 5 hours of sleep shift
operation, it will stop automatically.

CARE AND MAINTENANCE

I Cleaning the Indoor Unit and Remote
Control
• Wipe gently with a soft, dry cloth.
• Do not use water hotter than 40˚C or polishing fluid
to clean the unit.

I Cleaning the Air Filter

(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce cooling
or heating efficiency)
1
Remove dirt using a vacuum cleaner.
2
Wash back of the air filter with water.
3
If badly soiled, wash it with soap or a mild household
detergent.
4
Let it dry and reinstall it.
Be sure the "FRONT" mark is facing you.
* Damaged air filter.
Consult the nearest authorized dealer.
Part No.: CWD00112.
• Do not use benzene, thinner, scouring powder or
clothes soaked in caustic chemical to clean the
unit.