en
Flushing kit _______________________________________________________________________
6.2 -
Flushing kit connection for AC788PRO and ACS 752 stations
A/C Station
To set up the flushing kit refer to the above connection diagram and to the A/C
unit user manual instructions.
6.3 -
Flushing kit use
For usage of the flushing kit refer to the A/C unit user manual instructions.
7.0 -
AFTER FLUSHING
After flushing all individual components, reassemble them into the system.
Make sure you are working in a clean area when doing so. We recommend:
Renewing all O-Rings.
Replace the filter dryer.
Draining an renewing the compressor oil.
After reassembling the system, evacuate it, refill the system with oil and then with the
refrigerant.
Draw up a small service report, which lists all the maintenance work done during the
service to be kept by the customer; and a copy for your customer data.
40
High side red service hose
(without quick coupler)
Adapter fitting
LP R134a
Low side blue service hose
Red adapter hose
R134a
Blue hose 92"
Flushing
LS
adapter
A/C System
component
Flushing
HS
adapter
Operating instructions