en
Flushing kit _______________________________________________________________________
Screw the filter (4) to the flushing kit using Loctite 542. Tighten to a torque
of 15Nm.
6
Re-attach the flushing kit to the air conditioner service unit.
Connect LP service hose to filter outlet (6).
Connect HP service hose with the red adapter hose to flushing kit inlet (7).
Set a vacuum phase of 10 minutes and start this running.
Perform a leak test.
Filter replaced.
A/C Station
44
4
High side red service hose
(without quick coupler)
Low side blue service hose
7
Red adapter hose
Operating instructions