WARNING
DURING OPERATION THE PUMP EXHAUST AIR
FROM SIDE PORT OF AIR MOTOR.
DO NOT TOUCH THE EXHAUST PORT, WHILE THE
PUMP IS OPERATING.
10.1 FLUSHING BEFORE USE
ATTENTION
THE PUMP MUST BE CLEANED BEFORE USING IT FOR THE FIRST TIME, AFTER WORKING AND AFTER ANY COLOUR CHANGE.
Before to supply air to the pump, con-
1
firm that the ball valve is open and
the air regulator is adjusted to 0 bar.
OPEN
OPEN
Set the pressure regulator up slowly, to the minimum pressure required for the
4
straight and alternate movement of the pump.
ICON-M333N / ICON-M433N
UP
6
Close the drain valve.
CLOSE
Airless and Multi Spray iCon Pumps
Immerse the suction hose in the con-
2
tainer, containig cleaning liquid.
O BAR
ICON-A333N / ICON-A433N
UP
Flow out the cleaning liquid from
7
spray gun.
Open the drain valve for recirculation
3
of fluid.
OPEN
After flushing, drain the dirty liquid by
5
the drain hose.
8
Reset the air regulator to 0 bar.
CLOSE
CLOSE
O BAR
9