Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Part PJDI139:
D14MZ3000/
D14MZ3000-D
- 14 GPM
Injection Seal Kit
This kit contains:
(1) PJDI140 Check valve
assembly
(1) JDI100
Injection
sleeve o-ring
(1) PJDI138 Plunger with
seal
(1) JDI120
Injection stem
o-ring
Vea el reverso para
instrucciones en Español.
2090 Sunnydale Blvd.
Clearwater, FL 33765
800-523-8499 • 727-443-5404
www.dosatronusa.com
Kit Contents:
PJDI140:
JDI100: Injection
Check valve
sleeve o-ring
assembly
PJDI138:
Plunger
with seal
JDI120:
Injection stem
o-ring
We recommend cleaning all parts with warm
soapy water and a toothbrush before
installing the new parts.
Water normally lubricates the parts, but you
may use silicone on the o-ring to facilitate
insertion.
Check valve may be taken apart and
cleaned in between maintenance to remove
particles.
CAUTION: Parts may contain
STOP
concentrated chemicals. The use of
Proper Protective Equipment is recom-
mended when performing maintenance.
Instructions
(Parts included in kit noted in blue)
1.
Unscrew hose
nut (PDI934).
Unscrew injection
stem assembly
nut (PDI702) and
pull down on stem
to detach from
body of unit.
2.
Unscrew check valve
nut (PDI734) and
pull out check valve
assembly (PJDI140).
It should come out in
one piece. If not, be
sure to remove the
barb and check valve
and discard.
Unscrew locking nut (PDI733), remove
3.
"C" clamp (PDI727) by slightly sprea-
ding the opening and gently sliding it
over the threads. Unscrew adjusting
sleeve (PPDI036). Holding the sleeve
(PDI904), push up on the threaded part
of the white injection stem (PDI916)
and slide it out of the sleeve from the
top. Replace both sleeve and injection
and JDI120).
stem o-rings
(JDI100
JDI120
PDI916
JDI100
PDI904
PDI702
PDI727
PDI733
4.
Unscrew upper bell housing (PDI685),
and remove the piston assembly
(PCDI030). With the use of needle
nose pliers, carefully grip the plunger
by the thicker base and give ¼ of a turn
counter clockwise. Discard and replace
with the new plunger (PJDI138). Insert
the piston assembly back into the lower
body (PJDI113) and screw the upper
bell housing (PDI685) back on.
5.
Slide the injection stem (PDI916)
down into the sleeve (PDI904),
making sure the small key located
PDI702
on the bottom inside of the sleeve is
properly aligned with the longest
groove on the white stem. Holding
the black sleeve, pull down on the
white stem as far as it will go. Screw
PDI934
adjusting sleeve (PPDI036) back
onto the sleeve (PDI904).
PDI702
PJDI140
PDI734
6.
Insert new check valve (PJDI140)
at the bottom of the white stem,
making sure that the 4 white keys on
PDI685
the check valve seat next to the
4 keys on the bottom of the stem.
Screw check valve nut (PDI734)
back on.
PCDI030
Thicker
base
PJDI138
PJDI113
7.
Push complete injection stem assembly
in position at the bottom of the blue
body, making sure desired scale is
facing front of injector. Keys at the top
of the black sleeve should slide into
the slots at the bottom of the body.
Slide injection sleeve nut (PDI702)up
the sleeve and screw back on. Insert
hose back onto the bottom of the
check valve barb with compression
fitting in (PJDI140). Screw hose nut
(PDI934) back on.
To ensure hose is air-tight, you
may choose to carefully cut the top
of hose before reinserting.
Reinstall "C"
JDI120
clamp by sliding
it gently over the
thread at the
bottom of the
white stem.
PDI916
Rotate clamp until
it clicks into place.
Screw locking nut
JDI100
PDI733) back on.
PDI904
To remove
PDI702
o-ring easily
without tools,
squeeze it on either
side to raise the
seal, then slide it
PDI727
over the groove.
PDI733
PDI702
PJDI140
PDI734

Publicidad

loading

Resumen de contenidos para dosatron D14MZ3000

  • Página 1 (PDI904), nut (PDI934). Part PJDI139: making sure the small key located Unscrew injection PDI702 D14MZ3000/ on the bottom inside of the sleeve is stem assembly properly aligned with the longest D14MZ3000-D nut (PDI702) and groove on the white stem. Holding...
  • Página 2 Contenido del Kit: Desatornille la tuerca de seguridad Inserte la barra de inyección (PDI733), y remueva el anillo en (PDI916) dentro de la manga PJDI140: JDI100: O-Ring forma de “C” (PDI727). Desatornille (PDI904), asegurándose que el Válvula de la manga de la manga de ajuste (PPDI036).

Este manual también es adecuado para:

D14mz3000-d