Photo
F
1 Suction motor switch
2 Squeegee lifting/lowering selector
3 Hour meter
4 Battery charge indicator
5 Brush motor thermal breaker
6 Brush head unit lifting/lowering selector
7 Brush motor switch
8 Forward/reverse joystick selector
9 Electric horn
10
Key switch
11 Brush head unit lifting/lowering thermal
breaker
12 Speed adjustment potentiometer
13 Squeegee lifting/lowering thermal brea- ker
14 Control panel protection fuse
15 Operation emergency brake
16 Solotion tank low level warning light
Photo G
1 Squeegee bumper wheels (right/left)
2 Squeegee pression adjusting screw
3 Squeegee fast fixing knob
4 Opening knob of the box collector filter
5 Cover of the box collector filter
6 Squeegee inclination adjusting knob
7 Squeegee blades replacement knobs
8 Squeegee wheels (right/left)
9 Suction hose
Photo H
1 Solution water filter
2 Solution water tank drain valve
Photo I
1 Suction motor
2 Battery box
Photo L
1 Diagnostic signaling LED
Photo M1
1 Electromechanical brake fork lever
Photo M2
1 Unblocking lever
2 Pin
Photo M3 - M4 - M5
Electromechanical brake unblocking procedure
5.2.2
BATTERY
If supplied, the Pb-Acid (if not dry charged) or gel
batteries are ready to be installed:
Positive pole - red
Negative pole - black.
5.2.3
BATTERY CHARGER
If supplied, refer to the corresponding booklet.
5.3
ACCESSORIES
Your machine supplier can provide a complete
and updated list of all available accessories, such
as brushes, pad drivers, disks, etc.
6.
INSTALLATION INFORMATION
6.1
BATTERY PREPARATION
•
The technical features of the batteries
used must match those indicated in the tech-
nical fea- tures section. Using different batter-
ies may cause serious damage to the machine
or may require them to be charged more fre-
quently.
• During installation or when performing any
type of battery maintenance, the operator must
be equipped with adequate safety accessories to
prevent accidents. Work far from open flames, do
not short-circuit the battery poles, do not gener-
ate sparks and do not smoke.
The batteries are normally supplied full of acid
so- lution (for the Pb-Acid type) and ready for
use. In any case, follow the steps indicated in the
manual supplied with the battery and carefully
follow the instructions regarding safety and op-
erating proce- dures.
6.2
BATTERY INSTALLATION AND PREPA-
RATION
• These operations must be carried out by spe-
cialised personnel.
Make sure the two tanks are empty. If not, empty
them in accordance with the specific procedure.
Lift the recovery tank by 90°, making sure it is sta-
ble in that position. This provides access to the
battery compartment from the top.
Disconnect the Anderson connector of the bat-
tery wiring from the Anderson connector of the
machine wiring. Always hold the connectors with
the hands and never pull on the cables.
• Attach the battery wiring to the battery,
connecting the terminals only on the poles
marked with the same symbol (red wiring "+",
black wiring "-")! A battery short-circuit may
cause an explosion!
Run the cables toward the wiring outlet opening
(on one side of the box, only for Pb-Acid batteries),
tighten the terminals at the poles and cover them
with Vaseline.
Insert the battery putting the opening in the box
(only for the Pb-Acid battery) in a position to run
the electric wiring to the connector of the machine
wiring.
After checking that all the controls on the panel
are in position "0" or at rest, connect the battery
connector to the machine connector.
• Close the battery compartment (lowering the
33