Descargar Imprimir esta página

Not Enough Or Too Much Detergent; No Suction; Insufficient Suction; The Brush Motor Or The Suction Motor Doesn'T Stop - Comet Spa CRS 102 Manual De Instrucciones

Publicidad

 The brush motor switch is not selected.
 Press the button to activate the brushes.
 The machine is not moving forward and the
con- trol tripped to avoid damaging the floor.
 Press the advancement pedal.
 The brush motor thermal breaker tripped; the
motor overheated.
 Troubleshoot the cause (cords or similar items
that impede movement, surface too rough,
etc.) and press the reset breaker.
 The transmission belt is broken.
 Replace it.
 The motor relay or the brush motor is broken.
 Replace it.
9.2.4
NOT ENOUGH OR TOO MUCH DE- TER-
GENT
 The detergent solution tank is empty.
 Fill the detergent solution tank after having
emptied the recovery tank.
The brushes or the machine has stopped.
 Activate the brushes and press the accelerator.
 The flow adjustment lever is closed or almost
closed.
 Adjust/increase the detergent solution outlet
flow as required.
 The detergent solution filter is clogged.
 Clean the filter.
 The detergent feed conduit is clogged in some
point.
 Clean out the conduit by removing the dirt.
 The flow opening solenoid valve is burned.
 Replace it.
9.2.5

NO SUCTION

 The suction hose is not connected to the
squee- gee.
 Connect it correctly.
 The suction hose, the squeegee conduit or the
inspection compartment is clogged.
 Clean out and remove any obstructions from
the conduits.
 The suction motor is turned off.
 Activate it.
 The recovery tank is full.
 Empty it.
 The suction motor is not receiving electric
power or is burned.
 Check the connections and, for the latter case,
replace the motor.
9.2.6

INSUFFICIENT SUCTION

 The recovery tank cover was not correctly
tighte- ned.
 Tighten it correctly.
 The recovery tank drain hose plug is not per-
fectly closed.
 Close it correctly.
 The suction hose, the squeegee conduit or the
inspection compartment is clogged.
 Clean out and remove any obstructions from
the conduits.
9.2.7
THE BRUSH MOTOR OR THE SUC-
TION MOTOR DOESN'T STOP
 The relay switch is defective.
 Stop the machine, cutting off the main power
supply and disconnecting the main battery
connec- tor, and contact the technical service
centre.
9.2.8
THE SQUEEGEE DOESN'T CLEAN OR
DRY EFFICIENTLY
 The squeegee blades are worn or are dragging
solid dirt.
 Replace or clean them.
 The squeegee adjustment is not correct; the
advancement must be exactly perpendicular
to the running direction.
 Adjust the squeegee.
 The suction hose, the squeegee conduit or the
inspection compartment is clogged.
 Clean out and remove any obstructions from
the conduits.
9.2.9
THE BATTERY
DOESN'T WORK
 The battery charge doesn't start.
 Check that the battery charger is connected to
the battery. Consult the battery charger man-
ual.
9.2.10
THE BATTERIES DO NOT CHARGE OR DO
NOT HOLD A CHARGE
 At the end of the charging process, the battery
is not correctly charged (see the battery manu-
factu- rer's instruction-maintenance manual)
 Check the battery charger error message and
check the data indicated on the display (see the
battery charger's instruction manual).
 The batteries are new and do not generate
100% of the rated performances.
 The accumulator reaches the maximum perfor-
mance after 20-30 complete charge cycles.
 The electrolyte has evaporated and does not
completely cover the plates.
 Check the battery manufacturer's use and
main- tenance manual.
 There are significant differences in density
among the various elements.
 Replace the damaged battery.
Always consult the battery and battery charger
use and maintenance manual. If this does not
solve the problem, contact the authorised techni-
41
CHARGER

Publicidad

loading