TESTING PROCEDURES
Connect the product to testing wiring no. 4.
Check that any tester switch is set to OFF, that the knobs are all rotated in counter-clockwise direction
and that the rotating INDICATOR is set to R. Once the product has been connected, set the switch
+12 V Batt. to ON. Moving the GAS/BENZINA (GASOLINE) switch on the product to GASOLINE.
Set the switch +12 V Sc to ON. The RED LED GASOLINE on the product and the red LED OUT BENZ.
on the tester will turn on.
By setting the GAS/BENZINA (GASOLINE) switch on the product to GAS, the YELLOW LED GAS and
the Indicator on the product will turn on while on the tester the GREEN LED OUT GAS will turn on.
While running with GAS, by pressing the priming button on the product, the YELLOW LED CPU/CICC.
on the tester will turn on.
By setting the GAS/GASOLINE switch on the product to the central position, all the LEDs are off.
By rotating the INDICATOR knob from R to 4/4 and vice versa, you can test the various levels of the
product indicator.
Connect the product to testing wiring no. 2.
Check that any tester switch is set to OFF, that the knobs are all rotated in counter-clockwise direction
and that the INDICATOR knob is set to R.
Once the product has been connected, set the commutator to GAS.
Set the switch +12 V Batt. to ON. Set the switch +12 V Sc to ON. The YELLOW LED of the commutator
and the YELLOW LED CPU/CICC. of the tester will turn on for a priming period given by the trimmer
position located on the rear side of the commutator and the will turn off.
On the tester, the GREEN LED OUT GAS and the GREEN LED SERVICE (Sensor Power Supply) turn on.
On the commutator the RED LED RESERVE indicator remains on. By setting the INDICATOR switch
from R to 4/4 and vice versa, you can test the correct operation of the indicator.
By setting the switch on the commutator to the central position, the GREEN LED OUT GAS and the
LED SERVICE on the tester will turn off and all the LEDs on the product will turn off.
Set the switch of the commutator to GASOLINE. Only the RED LED GASOLINE on the commutator and
the RED LED OUT BENZ. on the tester will turn on. Set the switch of the product to the central
position. The RED LED OUT BENZ. on the tester will turn on. All the LEDs on the commutator are off.
By setting again the switch of the product to GAS, the initial priming condition and the turning-on of
the GREEN LEDs OUT GAS and LED SERVICE is present once again.
Set the switches to OFF.
Connect the product to testing wiring no. 1.
Check that any tester switch is set to OFF, that the knobs are all rotated in counter-clockwise direction
and that the rotating INDICATOR is set to R.
Once the product has been connected, set the commutator to GAS.
Set the switch +12 V Batt. to ON.
Set the switch +12 V Sc to ON. The YELLOW LED of the commutator and the GREEN LED OUT GAS of
the tester will turn on for a priming period given by the trimmer position located on the rear side of
the commutator and the will turn off.
On the commutator the indicator remains on anyway. By setting the rotating INDICATOR from R to
4/4 and vice versa, you can test the correct operation of the indicator.
Set the switch RPM to ON. The GREEN LED OUT GAS on the tester and the YELLOW LED on the
commutator will turn on.
By setting the switch on the commutator to the central position, the LEDs GAS and GASOLINE both of
the product and of the tester will remain on at the same time. Set the switch of the commutator to
GASOLINE. Only the RED LED GASOLINE on the commutator and the RED LED OUT BENZ. on the
tester will remain on, while the LEDs relating to GAS remain off.
Set the switch of the product to the central position.
The RED LED OUT BENZ. on the tester will turn on. All the LEDs on the commutator are off.
By setting the switch of the product to GAS, the YELLOW and GREEN LED and the indicator of the
commutator and the GREEN LED OUT GAS of the tester will turn on.
Set the switch RPM to OFF. The GREEN LED OUT GAS on the tester and the YELLOW LED on the
commutator will turn off. Set the switches to OFF.