SICK WL100-2 Manual De Operación página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
Commissioning
2
8017526 | SICK
Image 1: H
2
Mount the sensor and the reflector using suitable mounting brackets (see the SICK range of
accessories). Align the sensor and reflector with each other.
Note the sensor's maximum permissible tightening torque of < 0.5 Nm.
3
The sensors must be connected in a voltage-free state (V
graphics [B] must be observed, depending on the type of connection:
– Male connector connection: pin assignment
– Cable: core color
Image 2: B
Only apply voltage/switch on the power supply (V
have been completed. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (Graphic B):
Switching output Q (according to Graphic B):
WL100-2P (PNP: load -> M)
L = light switching
D = dark-switching
4
Align the sensor with a suitable reflector. Select the position so that the red emitted light
beam hits the center of the reflector. The sensor must have a clear view of the reflector,
with no object in the path of the beam [see E]. You must ensure that the optical openings of
the sensor and reflector are completely clear.
= 0 V). The information in the
S
> 0 V) once all electrical connections
S

Publicidad

Tabla de contenido
loading

Tabla de contenido