8008783.Z474 | SICK
Subject to change without notice
Figure 6: characteristic curve
1
Figure 7: sensing range areas
Table 8: Values for sensing range
2
PL80A
1
PL40A
1
3
Sensitivity setting
Sensor with potentiometer: open the sensor cover and protective hood, make sure that no
dirt has gotten into the sensor.
The sensitivity is adjusted with the potentiometer (type: without stop). Clockwise rotation:
operating reserve increased; counterclockwise rotation: operating reserve reduced. We rec‐
ommend setting the potentiometer to "Maximum". A lower operating reserve may be nec‐
essary for depolarizing surfaces.
The sensor is adjusted and ready for operation.
4
Time function setting
WL24-2xx4x: no time delay, t1 = time delay, t2 = time delay; for -2R: 0 = relay deactivated,
1 = relay active. Time delay selector switch can be set on the device according to
table
1.
Time stages: 0.5 ... 10 s can be adjusted.
2
WL24-2
0.03 ... 15 m
0.03 ... 11 m
6
COMMISSIONING
see
11