11
TECHNICAL DATA
14
Supply voltage V
S
Output current I
max.
Switching current (switching voltage)
Max. switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
Limit value; operation in short-circuit protection mains
1)
max. 8 A; residual ripple max. 5 Vss
Limit values; terminal connection: permissible wire
2)
cross-sections 0.14 to 1.5 mm2, male connector: ≤ 4 A
Usage category: AC-15, DC-13 (EN 60947-1)
3)
4)
With light / dark ratio 1:1
Signal transit time with resistive load
5)
6)
Reference voltage DC 50 V
Rated voltage AC/DC 250 V, overvoltage category II
7)
8)
A = UV-connections reverse polarity protected
B = inputs and output reverse-polarity protected
C = Interference suppression
WL24-2B / -2V
-2R
DC 10 ... 30 V
AC / DC 20 ...
1)
250 V
2)
100 mA
4 A (250 V AC), 4
A (24 V DC)
1000 Hz
10 Hz
4)
4)
≤ 500 µs
≤ 10 ms
5)
6)
IP67: -2B2x0,
IP67: -2R2x0,
-2B3x3, -2V2x0
-2R5x8
IP69K: -2B4x0,
-2V5x0
II
II
7)
8)
A,B,C
A,C
9)
9)
–40 °C ...
–40 °C ...
+60 °C
+60 °C
8008783.Z474 | SICK
Subject to change without notice
3)