WARNINGS
A. To reduce risk of electrical shock, do not remove cover. Refer servicing to qualified service personnel.
B. To avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth
ground.
C. The ENDO STRATUS® irrigation pump is not suitable for use in the presence of a flammable anesthetic mixture with
oxygen.
D. The ENDO STRATUS irrigation pump shall be sold only by prescription for use by physicians/clinicians who are
trained regarding the amount of water to use for irrigation and infusion.
E.
Always watch for abnormal flow rates and adjust the flow rate as necessary. If an unusual flow rate remains after
adjustments have been made, then stop the procedure and investigate.
F.
Only qualified medical personnel in an acceptable medical facility should operate the ENDO STRATUS irrigation
pump.
G. The ENDO STRATUS irrigation pump should be connected to a properly grounded 120V receptacle marked
"Hospital Grade" or "Hospital Only, " otherwise grounding reliability cannot be achieved.
H. Extreme precaution must be taken when handling liquids around electrical equipment. DO NOT operate the
ENDO STRATUS irrigation pump if liquid has been spilled on the unit.
I.
The ENDO STRATUS irrigation pump should not be used adjacent to or stacked with other equipment other
than another ENDO STRATUS device. Electromagnetic or other interference may occur between the
ENDO STRATUS irrigation pump and other electronic devices. If stacked or adjacent use is necessary, the
equipment or system should be observed to verify normal operation in the configuration in which it will be used.
J.
The ENDO STRATUS irrigation pump should only be used in conjunction with other equipment whose safety
against leakage currents has been established.
K. The instructions contained in the operating manuals of any equipment to be used in conjunction with the
ENDO STRATUS irrigation pump must be followed to avoid any possible hazard from incompatibility.
L.
The instructions for use described in this manual MUST be followed. Otherwise, compromised safety, malfunction,
injury to the operator and/or patient, or costly damage to the unit and other equipment may occur.
M. The ENDO STRATUS irrigation pump must be connected to an appropriate power source when loss of power
source would result in an unacceptable risk.
CAUTION
A. If emergency or abnormal function occurs, immediately turn off the power to the unit.
B. Field-servicing of the ENDO STRATUS irrigation pump is limited to the replacement of the power cords,
water bottle holder and heater assemblies, pump heads, foot pedals and fuses.
C. Remove power from the device before initiating any field servicing of the replacement parts.
D. There are no user serviceable parts inside the ENDO STRATUS irrigation pump unit. Repairs to the
ENDO STRATUS irrigation pump should only be performed by qualified service personnel.
E.
Do not use the device if the enclosure is damaged or enclosure integrity has been compromised.
F.
Do not attempt to operate the device before reading and understanding all sections of this manual.
G. Medical electrical equipment needs special precautions regarding EMC and needs to be installed and put into
service according to the EMC information provided in Section X.
H. Portable and mobile radio frequency (RF) communications equipment can affect medical electrical equipment.
Do not expose the device to sources of electromagnetic interference such as CT equipment, diathermy equipment,
cellular phones, RFID tags and metal detectors.
EN - 5
IFU-51 / REV G