Specifications cont.
Function
Range
60.00nF
Capacitance
(Autoranging)
600.0nF
6.000µF
60.00µF
600.0µF
6000µF
Input Protection:
600V DC or 600V AC rms
* Accuracy is not specified below 6nF
Frequency through test leads when meter is set to Hz %
Function
Range
6.000Hz
Frequency
(Autoranging)
60.00Hz
600.0Hz
6.000kHz
60.00kHz
600.0kHz
10.00MHz
Input Protection:
600V DC or 600V AC rms
Sensitivity:
>5V AC rms
Duty Cycle through test leads when meter is set to Hz%
Function
Range
0.5% to 99.9%
Duty Cycle
Input Protection:
600V DC or 600V AC rms
Pulse Width:
100µS to 100mS
Frequency:
10Hz to 10kHz
Sensitivity:
>5V RMS
Resolution
Accuracy ±
(% of reading + digits)
10pF
±(5.0% +30 digits) *
0.1nF
±(3.0% +5 digits)
1nF
±(3.0% +5 digits)
10nF
±(3.0% +5 digits)
0.1µF
±(4.0% +10 digits)
1µF
±(4.5% +10 digits)
Resolution
Accuracy ±
(% of reading + digits)
0.001Hz
±(1.0% +5 digits)
0.01Hz
±(1.0% +5 digits)
0.1Hz
±(1.0% +5 digits)
1Hz
±(1.0% +5 digits)
10Hz
±(1.0% +5 digits)
100Hz
±(1.0% +5 digits)
0.01MHz
±(1.0% +5 digits)
Resolution
Accuracy ±
(% of reading + digits)
0.1%
±(1.2% +10 digits)
17
Specifications cont.
Frequency through test leads when meter is set to AC voltage
Function
Range
10Hz to 10kHz
Frequency
(Autoranging)
20% to 80%
Duty Cycle
Input Protection:
1000V AC rms or 1000VDC
Duty Cycle Sensitivity:
10Hz to 1kHz
Sensitivity:
>15V AC rms
Frequency through jaws when meter is set to AC current
Function
Range
40Hz to 1kHz
Frequency
(Autoranging)
20% to 80%
Duty Cycle
Maximum Input:
1000A AC rms or 1000A DC
Duty Cycle Sensitivity:
10Hz to 1kHz
Sensitivity:
>50A (600A range)
>500A (1000A range)
Function
Range
-4 to 1400°F
Temperature
-20° to 760°C
Input Protection:
600V DC or 600V AC rms
Sensor:
Type K Thermocouple
Accuracy
(% of reading + digits)
±1.0% ±5 digits
±1.5% ±10 digits
Accuracy
(% of reading + digits)
±1.0% ±5 digits
±1.5% ±10 digits
Resolution
Accuracy ±
(% of reading + digits)
0.1°F/1°F
±3% ±9°F
0.1°C /1°C
±3% ±5°C
18