Charge indicators: DCB107, DCB112, DCB113, DCB115
charging
fully charged
hot/cold pack delay*
* DCB107, DCB112, DCB113, DCB115: The red
light will continue to blink, but a yellow indicator
light will be illuminated during this operation.
Once the battery has reached an appropriate
temperature, the yellow light will turn off and the
charger will resume the charging procedure.
The compatible charger(s) will not charge a faulty
battery pack. The charger will indicate faulty battery
by refusing to light or by displaying problem pack or
charger blink pattern.
NOTE: This could also mean a problem with a
charger.
If the charger indicates a problem, take the charger
and battery pack to be tested at an authorised
service centre.
HOT/COLD PACK DELAY
When the charger detects a battery that is too hot
or too cold, it automatically starts a Hot/Cold Pack
Delay, suspending charging until the battery has
reached an appropriate temperature. The charger
then automatically switches to the pack charging
mode. This feature ensures maximum battery life.
A cold battery pack will charge at about half the
rate of a warm battery pack. The battery pack will
charge at that slower rate throughout the entire
charging cycle and will not return to maximum
charge rate even if the battery warms.
LITHIUM-ION BATTERY PACKS ONLY
XR Li-Ion tools are designed with an Electronic
Protection System that will protect the battery
against overloading, overheating or deep discharge.
The tool will automatically turn off if the Electronic
Protection System engages. If this occurs, place
the lithium-ion battery on the charger until it is fully
charged.
Important Safety Instructions for All
Battery Packs
When ordering replacement battery packs, be sure
to include catalog number and voltage.
The battery pack is not fully charged out of the
carton. Before using the battery pack and charger,
read the safety instructions below. Then follow
charging procedures outlined.
READ ALL INSTRUCTIONS
• Do not charge or use battery in explosive
atmospheres, such as in the presence of
flammable liquids, gases or dust. Inserting
or removing the battery from the charger may
ignite the dust or fumes.
• Never force battery pack into charger. Do
not modify battery pack in any way to fit
into a non-compatible charger as battery
pack may rupture causing serious personal
injury.
• Charge the battery packs only in D
chargers.
• DO NOT splash or immerse in water or other
liquids.
• Do not store or use the tool and battery
pack in locations where the temperature
may reach or exceed 40 ˚C (104 ˚F) (such
as outside sheds or metal buildings in
summer).
WARNING: Never attempt to open the
battery pack for any reason. If battery
pack case is cracked or damaged,
do not insert into charger. Do not
crush, drop or damage battery pack.
Do not use a battery pack or charger
that has received a sharp blow, been
dropped, run over or damaged in any
way (i.e., pierced with a nail, hit with a
hammer, stepped on). Electric shock
or electrocution may result. Damaged
battery packs should be returned to
service centre for recycling.
CAUTION: When not in use, place
tool on its side on a stable surface
where it will not cause a tripping or
falling hazard. Some tools with large
battery packs will stand upright on the
battery pack but may be easily knocked
over.
SPECIFIC SAFETY INSTRUCTIONS FOR LITHIUM-ION
(LI-ION)
• Do not incinerate the battery pack even
if it is severely damaged or is completely
worn out. The battery pack can explode in
a fire. Toxic fumes and materials are created
when lithium-ion battery packs are burned.
• If battery contents come into contact with
the skin, immediately wash area with mild
soap and water. If battery liquid gets into the
eye, rinse water over the open eye for
15 minutes or until irritation ceases. If medical
attention is needed, the battery electrolyte
is composed of a mixture of liquid organic
carbonates and lithium salts.
english
WALT
e
33