4
TEST INSTALLED FITTING
• With HANDLE (1) in OFF position, turn on WATER SUPPLIES (3) and check all connections for leaks.
.
• Remove AERATOR (2) using KEY (5)
• Operate HANDLE (1) to fl ush water lines thoroughly.
.
• Reinstall AERATOR (2)
CHECK DRAIN CONNECTIONS
• Operate DRAIN STOPPER (4) and fi ll lavatory with water. Check that DRAIN STOPPER (4) makes a good seal and retains
water in sink. Check all drain connections and "P" trap for leaks.
1
WASTE
OUTLET
3
Tighten if necessary.
ON
OFF
COLD
2
HOT
5
4
3
"P" TRAP
M965834 Rev. 1.1 (4/18)
- 4 -
2
REVISE EL FUNCIONAMIENTO DEL ELEVADOR
• Accione la TAPÓN (1) para verifi car que el TAPÓN (1)
se abra y se cierre.
3
REALICE LAS CONEXIONES DE SUMINISTRO DE AGUA Y DRENAJE
• Conecte los TUBOS DE SUMINISTRO FLEXIBLES (1, 2) directamente
a los suministros de la pared. Los conectores de los suministros
son de compresión de 9.5 mm (3/8"). Conecte la MANGUERA DE
SUMINISTRO (1) (marcada con una banda roja) a la válvula de
pared de agua caliente y la MANGUERA DE SUMINISTRO (2)
(marcada con una banda azul) a la válvula de pared de agua fría.
• Los suministros de la llave miden 610 mm (24") desde la base
de la llave.
Nota: Si se necesita un suministro más largo, el instalador debe
comprar las piezas adicionales por separado.
Import ante: Si las MANGUERAS DE SUMINISTRO (1, 2)
son demasiado largas, forme un bucle como se
muestra en la fi gura para evitar que se doblen.
• Conecte el tubo de descarga con un DIÁM. EXT. de
31.7 mm (1-1/4") del DESAGÜE CON ELEVADOR
a la salida de desagüe.
610 mm
(24")
2
1
COMPRESIÓN 9.5 mm (3/8")
CALIENTE
FRÍA
M965834 SP Rev. 1.1 (4/18)
- 17 -