3
WIRING &
CONNECTION
The unit requires connection to a 240Vac
50Hz mains electricity supply. This is best
achieved by connecting the unit to the
domestic lighting circuit. It is suggested that
3-core round flexible cable of at least
1mm
2
gauge is used. It is also allowable
for the unit to be connected to the
domestic socket ring main, though it
is suggested that a 5 amp fused spur is
used in this case.
IMPORTANT
ALWAYS switch OFF the mains power
BEFORE attempting to install or maintain
the PIR. If in doubt,
consult a qualified electrician.
All installations shall comply with
National Wiring Regulations.
NOTE: when connecting to METAL LIGHT
FITTINGS ensure an earth conductor is
connected to provide earth continuity to
the metal fitting.
L
Fig. 8
L1
N
Auto / Off Wiring in this manner
provides the following lighting options:
Automatic operation (Switch closed)
Permanently Off (Switch open)
INDOOR SWITCH
FOR PERMANENT OFF
OVERRIDE
(OPTIONAL)
LIVE
EARTH
NEUTRAL
Fig. 9
Additional feature - when in Auto mode,
switching off, then back on, will result in
the lamp illuminating for the pre-set time
period. This is ideal for lighting the way
when leaving premises.
Auto / On Provides the following
lighting options:
Automatic operation (Switch open)
Permanently On (Switch closed)
LIVE
EARTH
NEUTRAL
INDOOR SWITCH
FOR PERMANENT ON
Fig. 10
OVERRIDE (OPTIONAL)
4
L
L1
N
L
L1
N
LAMP
LAMP