Electrical safety

12
Disconnect from all sources of electrical power!
Switch off the power supply before working on the circuit.
Please note that electrical energy may be stored in individual components.
Further information on this issue is available in the data sheets and operating
instructions included with the components.
Caution!
Capacitors inside the device may still be charged even after being disconnected
from all sources of voltage.
Risk of death in case of interrupted protective conductor!
The protective conductor (yellow-green) must not be interrupted,
either inside or outside of the hydraulic power pack.
The insulation of the protective conductor must never be damaged
or removed.
Hazard-free operation of the device is no longer possible in the case of
Visible damage
Malfunction
Incorrect storage
Incorrect transport.
Immediately remove the mains plug from the electric outlet.
Protect the device against inadvertent restart.
The hydraulic power pack must be switched off and its mains plug must be removed
from the electric outlet before installation, repair, maintenance and cleaning work.
The electric motor's ventilation slots must not be covered!
Set the hydraulic power pack up so that switches and interrupters are easy to
activate.
WARNING
CAUTION