2.4. EMC requirements
InGECOn EMS Home units are equipped with the necessary filtering elements to comply with EMC requirements
for domestic applications in order to prevent disturbances in other equipment outside the installation.
2.5. Acoustic contamination
The unit produces a slight buzz when in operation.
Do not place it in an occupied room, or on light supports which might amplify this buzz. The mounting surface
must be firm and appropriate for the weight of the unit.
2.6. Wiring diagram of the system
External isolating
switch
Inverter
grid relay
grid relay
+
J56
–
EMS Home
Transformer
(optional)
Ac out