4.2. Display

10:23
10:23
Percentage of
battery charge
Battery status, voltage and current
* may only be displayed when the EMS Home is connected to a public grid.
The data that appears on the main screen of the InGECOn EMS Home units is detailed below.
Percentage of battery charge
This shows the current state of charge of the battery bank as a percentage.
Battery status, voltage and current
The status may have various values:
C
Charge
D
Discharge
V
Absorption charge
F
Flotation charge
E
Equalization charge
Percentage and reason for charge
If the EMS Home is connected to a public grid, the charge percentage and reason for limiting the most restrictive
charge will be displayed. The following explains the various reasons for limiting the charge
CFG
Limitation due to user settings.
BAT
Limitation due to the state of charge of the battery.
TMP
Limitation due to high temperature in the unit.
COM
Limitation due to interface settings.
External communications device
This indicates that the inverter is operating to the interface setting.
If the symbol flashes, this means that communications have been lost. As a result, battery charging/discharging will
stop.
ABH2000IKE02_ - User manual
Percentage and reason for limiting the load*
current date and time
Power, voltage and frequency fed to the
03/08/13
03/08/13
External communications device
public grid
Ingeteam
English - 55