Flashing warning signal for 1 to 10 seconds prior to every manoeuvre.
Condominium function for partial open command (PED)
Enabled. Partial commands are ignored during gate opening.
Enabling operator present function
Disabled.
stops when the button is released.
Gate open indicator / photocell test function and "battery saving"
The indicator is off when the gate is closed, and steadily lit during manoeuvres and when the gate is
open.
If the gate is stopped in an intermediate position, the lamp extinguishes twice every 15 seconds.
Set
if the output SC
Set to
if the output SC
When the gate is completely open or closed, the control unit deactivates any accessories connected to
terminal SC to reduce battery consumption.
Set to
if the output SC
5.
Setting deceleration MOTOR 1
Setting deceleration MOTOR 2
01= the gate decelerates near stops and the limit switch (if installed).
...
05= the gate decelerates long before stops and the limit switch (if installed).
Adjusting LEAF 1 position control when completely opens or closes
(open or closed) mechanical stop. The position of LEAF 1 is calculated by the system from the number
of motor revolutions and the motor reduction gear ratio.
Warning
N.B.: with BR21 automation systems, with the gate leaf in the completely closed position, adjust the
inner mechanical stop so that the lever of the gear motor can move by a few millimetres.
Adjusting LEAF 2 position control when completely opens or closes
(open or closed) mechanical stop. The position of LEAF 2 is calculated by the system from the number
of motor revolutions and the motor reduction gear ratio.
Warning
N.B.: with BR21 automation systems, with the gate leaf in the completely closed position, adjust the
inner mechanical stop so that the lever of the gear motor can move by a few millimetres.
Motor revolutions.
Partial opening adjustment (%)
N.B.: with double leaf swing gate installations, this parameter is set by default as the completely open
position of LEAF 1.
With single leaf swing gate installations, this parameter is set to 50% of total opening.
From 15% to 99% of total gate travel.