6.4 LCD Menus
(Also refer to Table 1, Quick Reference Chart (QRC) located after
Section 9.0)
A. Normal Operation
Screen 8
(See Screen 8.) LCD screen on a Z-Class Torque Wrench pump.
CB has booted successfully (OK); the pressure reading is 0 psi.
Enter into the menus by pressing the Menu button. See QRC step
#1 or #12.
B. "Auto Mode" Menu
Screen 9
AUTOMODE
SET
OFF
(Screen 9) This screen allows the operator to toggle the torque
wrench Auto Cycle mode ON or OFF. With Automode OFF, the
menu Set Pres (Firmware 5.5 and earlier) or HI PRESS (Firmware
5.6 and later) will not be available and the Set Pres / HI PRESS
pressure value has no effect on the pump. Switch it ON or OFF by
pressing either the Down (Up) Arrow button. Note: Firmware 5.6
and later - Setting the value to ON also changes the Normal
Operations menu text message from "OK" to "AUTO" Save
setting and step forward by pressing the Menu button. See QRC
step #2.
C. "Set Press" or "HI PRESS" Menu (Only available with
Automode ON)
Screen 10
SET PRES
SET
7500
OK
0
PSI
PSI
(See Screen 10.) This screen allows the operator to set the
Advance port pressure value the torque wrench will Auto Cycle at.
Changes in increments of 50 psi (3.5 bar) by pressing either Down
(Up) Arrow button or keep either button pressed for speed setting.
Maximum pressure value is 11,600 psi (800 bar) for (-E) pumps
and 10,000 psi (700 bar) for (-Q) pumps. NOTE: Firmware 5.5 and
earlier - the hidden calibration menu for the digital gauge is
accessed from this menu. Save setting and step forward by
pressing the Menu button. See QRC step #2A.
D. "Units" Menu
Screen 11
SET
(See Screen 11.) This screen allows the operator to set the unit of
pressure-measurement by pressing the Down (Up) Arrow buttons.
PSI, BAR, Mpa are the options with PSI being the default. Save
setting and step forward by pressing the Menu button. NOTE:
Firmware 5.6 and later - the hidden calibration menu for the digital
gauge is accessed from this menu. See QRC step #3.
E. "Motor" Menu
Screen 12
4.8
HOURS CYCLES
(See Screen 12.) This screen allows the operator to read the
number of hours (On/Off cycles) the motor has been operated.
Toggle between hours and cycles by pushing either the Down or
Up Arrow buttons. Step forward by pressing the Menu button. See
QRC step #4.
_________________________________________________________
General note for all hour and cycle displays:
HOURS DISPLAYED
- up to 9999.9 the display will show decimal hours
- between 10,000 - 99,999 whole hours will be displayed
(decimal "." is not displayed).
- over 99,999 hours the meter starts over at 0.0 reading
decimal hours
CYCLES DISPLAYED
- over 99,999 cycles the meter starts over at 0
_________________________________________________________
7
UNITS
PSI MPa
BAR
MOTOR