Detergent (Axp/Eds) System - Nilfisk-Advance Adphibian Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

A-14 / ENGLISH
DETERGENT (AXP/EDS) SYSTEM PREPARATION AND USE
COMMON INSTRUCTIONS:
Pressing and releasing the Detergent Switch (B) while the solution
system is active will cause the detergent system to alternately turn
on and off. The system should be purged of previous detergent
when switching to a different detergent. SERVICE NOTE: Move
machine over fl oor drain before purging because a small amount of
detergent will be dispensed in the process.
To Purge When Changing Chemicals:
1
Disconnect and remove the detergent cartridge.
2
Turn the Key Switch (A) ON and press the Detergent Switch (B) and
the Solution/Pre-Spray Switch (C) down for at least 2 seconds. NOTE:
Once activated the purge process takes 30 seconds. See illustration on
next page for Detergent System indicators. Normally one purge cycle is
adequate to purge the system.
To Purge Weekly:
1
Disconnect and remove the detergent cartridge. Install and connect a
Cartridge fi lled with clean water
2
Turn the Key Switch (A) ON and press the Detergent Switch (B) and
the Solution/Pre-Spray Switch (C) down for at least 2 seconds. NOTE:
Once activated the purge process takes 30 seconds. See illustration on
next page for Detergent System indicators. Normally one purge cycle is
adequate to purge the system.
When the Detergent Cartridge is almost empty a Display Panel (D1)
indicator will come on. This "Low Detergent" indicator will remain
on until you reset the system. Once this indicator comes on you
should be able to simply pour an entire gallon bottle of detergent
into the Cartridge to refi ll without worrying about measuring. NOTE:
Only reset the system when the cartridge is full. When switching
cartridges, the "Low Detergent" indicator is only accurate if the
replacement cartridge is at the same level as the cartridge being
replaced.
To Reset:
1
Turn the Key Switch (A) ON and hold the Detergent Switch (B)
down for 2 seconds. See illustration on next page for Detergent
System indicators.
NON-REFILLABLE CARTRIDGE SPECIFIC INSTRUCTIONS:
Remove the Cap (AA) and place the cartridge in the detergent box.
Install the Dry Break Cap (BB) as shown.
A-14 - 56041711 - Adphibian
/ AX 651 Combi EDS
REFILLABLE CARTRIDGE SPECIFIC INSTRUCTIONS:
Fill the detergent cartridge with a maximum of 1.25 gallons (4.73
Liters) of detergent. SERVICE NOTE: Remove the detergent cartridge
from the detergent box prior to fi lling to avoid spilling detergent on the
machine.
It is recommended that a separate cartridge be used for each detergent
you plan to use. The detergent cartridges have a white decal on them
so you can write the detergent name on each cartridge to avoid mixing
them up. The detergent cartridge has a Magnetic Slider (CC) on one
end that needs to be set to the proper dilution ratio according to the
dilution instructions on the manufacturer's bottle. Slide the Magnet
Slider (CC) to the appropriate location on Detergent Dilution Ratio
Decal (DD). When installing a new cartridge, remove the Cap (AA) and
place the cartridge in the detergent box. Install the Dry Break Cap (BB)
as shown.