BEFORE CALLING FOR SERVICE
The following are not defects.
A hissing noise or hol-
This sound is generated from the
low sound:
refrigerant flowing within pipes.
This noise is generated from the
A squeaking noise:
unit when it is expands or contracts
with temperature changes.
Such odor as tobacco, cosmetics,
Odor:
or foods may accumulate in the
unit.
The unit does not start
To prevent overloading the com-
nor change operation
pressor motor, the unit will be
mode immediately:
stopped for more than 3 minutes.
MALFUNCTION ANALYSIS
Malfunction code
H8 Tank is full of water.
1. Pour out the water inside tank.
2. If "H8" still exits, please contact
professional person to maintain
the unit.
F1 Malfunction of ambient
Please contact professional person
temperature sensor.
to deal with it.
F2 Malfunction of evapora-
Please contact professional person
tor temperature sensor.
to deal with it.
F0 1. Refrigerant is leaking.
1. Re-energize the unit after turning
off and pulling out the plug for
30min;
2. System is blocked.
2. If there's still malfunction, please
contact after-sales service.
1. If ambient temperature is too
H3 Overload protection for
high, power off the unit and then
compressor.
energize it for operation after the
ambient temperature drops to be-
E8 Overload malfunction
low 35°.
2. Check if the evaporator and con-
F4 Outdoor tube
denser are blocked by some ob-
temperature
jects. If yes, take away the ob-
sensor is open/
jects, power off the unit and then
short-circuited.
energize it for operation.
3. If the malfunction still occur,
please contact our after-sales
service center
All manuals and user guides at all-guides.com
12. SPECIFICATIONS
*Conform to EN-14511:2013
NOTE: Cooling air capacity will vary according to temperature and
13. VENTING KIT ACCESSORIES
If the unit is to be used exclusively in one space, the cooling effi-
ciency will be enhanced by using the following venting kit accesso-
ries.
USING EXHAUST DUCT SET (Fig. H)
1.
2.
3.
4.
5.
5
MODEL
TAD-120E
Single Phase
POWER SOURCE
220~240 V, 50 Hz
2.05 kW
COOLING CAPACITY
(7,000BTU)
COOLING POWER INPUT
780 W
EE Class / EER*
A / 2.63
POWER CONSMPTION IN
109 W
THERMOSTAT-OFF MODE
POWER CONSUMPTION IN
0.5 W
STANDBY MODE
DEHUMIDIFYING
1.0 L/h
CAPACITY
OPERATING CURRENT
3.5 A
AIR FLOW (MAX.)
320 m
3
/h
FOR ROOMS UP TO
50 - 70 m
3
OPERATING TEMP. RANGE
16°C ~ 35°C
SOUND POWER LEVEL
63 dB
UNIT PROTECTION
IP X0
FUSE RATING
250V; 3,15A
315 × 770 ×
DIMENTIONS (W×H×D)
395 mm
WEIGHT
24.0 kg
COMPRESSOR
ROTARY
REFRIGERANT
R-410A / 410g
GWP
2088
humidity of the room.
Prepare the below accessory.
H1 Exhaust duct hose adapter nozzle. (Fix to unit)
H2 Exhaust duct hose
H3 Exhaust nozzle (upper) + Exhaust nozzle (lower)
To fix the Exhaust nozzle (upper) and the Exhaust nozzle (low-
er) together, press the clasp forcibly into the groove. (Fig. H4)
Insert one end of exhaust duct hose (flexible tube) (H2) into
exhaust duct hose adapter nozzle (H1) by turning it counter
clockwise. And install exhaust nozzle (upper + lower) (H3) into
another side of exhaust duct hose. (Fig. H5)
Face the side with "TOP" upwards.Insert exhaust duct hose
adapter nozzle into the groove of exhaust outlet until you hear
a sound. (Fig. H6)
Place the exhaust hose outdoors. (Fig. H7)
NOTE:
Place the unit as close as possible to the window or
door. (H5, H6, H7)
ENGLISH
TAD-126E
TAD-129E
Single Phase
Single Phase
220~240 V, 50 Hz
220~240 V, 50 Hz
2.64 kW
2.93 kW
(9,000BTU)
(10,000BTU)
1,010 W
945 W
A / 2.61
A
/ 3.10
+
102 W
39 W
0.5 W
0.5 W
1.43 L/h
1.6 L/h
4.5 A
4.3 A
330 m
3
/h
360 m
3
/h
65 - 90 m
3
70 - 95 m
3
16°C ~ 35°C
16°C ~ 35°C
64 dB
65 dB
IP X0
IP X0
250V; 3,15A
250V; 3,15A
315 × 770 ×
390 × 820 ×
395 mm
405 mm
27.5 kg
36.0 kg
ROTARY
ROTARY
R-32 / 350g
R-32 / 550g
675
675