< 6 l/hr), the pump switches off completely. When the leakage on the
pressure side is eliminated, the pump must be unplugged and plugged in
again in order to be operational again.
Stop valve:
The integrated stop valve closes as soon as no more water is drawn.
Thermal protection switch:
In the event of an overload, the pump is switched off by the built-in
thermal motor protection. After sufficient cooling of the motor, the pump
is operational again.
4. STORAGE
To put into storage:
v Store the pump away from frost before the first frost sets in.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling
collection centre.
5. MAINTENANCE
Clean inlet filter and suction foot [ Fig. M1 ]:
DANGER! Electric shock!
There is a risk of injury from electric shocks.
v Before maintenance, disconnect the submersible pressure
pump from the mains.
1. Turn out the 8 screws
6
2. Remove the suction foot
7
8
3. Remove the inlet filter
and the spacer ring
4. Clean the suction foot
7
, inlet filter
5. Place the spacer ring
9
onto the pump in such as way that tab
fits into the hole in the pump.
6. Put the inlet filter
8
onto the pump.
7
7. Put the suction foot
onto the pump and screw in the 8 screws
For safety reasons, a damaged turbine must only be replaced by
GARDENA Service.

6. TROUBLESHOOTING

DANGER! Electric shock!
Es besteht Verletzungsgefahr durch elektrischen Strom.
v Vor dem Beheben von Störungen die Tauch­Druckpumpe vom
Netz trennen.
Problem
Possible Cause
The pump does not deliver
Air cannot escape as the
any water
pressure line is closed.
Air cushion in suction foot.
Inlet filter or suction foot
blocked.
Pump overheated:
Thermal protection switch
switched pump off due to
overheating.
Lack of water:
Dry run protection switched
the pump off due to
insufficient water level.
8
1476-20.960.08 Short A4.indd 8
with a screwdriver.
from the pump.
9
from the pump.
8
and the spacer ring
9
Remedy
v Open pressure line (e. g. bent
pressure hose).
v Unplug mains cable and plug
in again.
v Disconnect mains plug, clean
inlet filter and suction foot
(see 5. MAINTENANCE).
v Disconnect mains plug, clean
inlet filter and suction foot
(see 5. MAINTENANCE).
Observe max. media tempera-
ture (35 °C).
The pump is only operational
when it is submerged at least
12 cm.
v Submerge pump at least
12 cm in water.
Problem
The pump does not deliver
any water
Delivery rate suddenly
decreases
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.
7. TECHNICAL DATA
Submersible Pressure Pump Unit
Rated Power
Max. delivery capacity
Max. pressure
(= switch-off pressure)
Max. delivery height
Switch-on pressure
Max. submersion depth
Power cable
Pump connection
Minimum submersion depth
on commissioning
Weight without cable
(approx.)
Fastening rope
.
Max. media temperature
0
Mains voltage /
Mains frequency
6
.
Sound power level L
1)
WA
Measuring process complying with:
8. ACCESSORIES
GARDENA 2- / 4-Way Valve
GARDENA Hose Clamp
GARDENA Hose Clamp
GARDENA
Pump Connection Set
GARDENA Tap Connector
GARDENA Hose Connector
GARDENA
Pump Connection Set
9. SERVICE / WARRANTY
Service:
Please contact the address on the back page.
Warranty:
In the event of a warranty claim, no charge is levied to you for the services
provided.
GARDENA Manufacturing GmbH offers a two-year warranty (effective
as of the date of purchase) for this product. This warranty includes all
significant defects of the product that can be proved to be material or
manufacturing faults. This warranty is fulfilled by supplying a fully func-
Possible Cause
Remedy
Leakage on the pressure side:
v Check pressure hose and all
Flow control switched the
consumers on the pressure
pump off (flow < 6 l/hr).
side for tightness. Unplug
pump and plug in again.
Power supply interrupted.
v Check fuses and electrical
plug-in connections.
Stop valve jammed.
v Flush outlet area with clear
water and free stop valve.
Inlet filter or suction foot
v Disconnect mains plug,
blocked.
clean inlet filter and suction
foot (see 5. MAINTENANCE).
Lack of water:
The pump is only operational
Dry run protection switched
when it is submerged at least
the pump off due to
12 cm.
insufficient water level.
v Submerge pump at least
12 cm in water.
Value (Art. 1476)
W
1050
l/h
6000
bar
4.5
m
45
bar
2.6 ± 0.2
m
12
m
15 H07RN-F
mm
33.3 (G 1" female thread)
cm
12
kg
8.0
m / mm
15 length / ∅ 5
°C
35
V / Hz
230 / 50
dB(A)
46
60335-1
1)
For parallel connection for more than one hose
or connected devices.
For 25 mm (1" ) hoses via the connection nipple. Art. 7192
For 19 mm (³⁄₄" ) hoses via the connection nipple. Art. 7191
For 13 mm (¹⁄₂" ) hoses via the GARDENA
Connection System.
For 16 mm (⁵⁄₈" ) hoses via the GARDENA
Connection System.
For 19 mm (³⁄₄" ) hoses via the GARDENA
Connection System.
Art. 1210 / 1194
Art. 1750
Art. 18202
Art. 18216
Art. 1752
16.04.18 18:59