Continued type
Electrical power supply
Rated voltage
Voltage range
Current consumption
Protected against incorrect
polarity
Protection against electric shock
(protection against direct and in
direct contact as per IEC/DIN EN
60204−1)
Interface to the SPC200
Specification
Connection
Max. cable length
Pin assignment
Care and maintenance
18
SPC200−MMI−1F
Phoenix Combicon 3x3.81
24 V
18 ... 36 V
Approx. 100 mA
Yes
by means of PELV circuits
(Protective Extra−Low Voltage)
RS 232 interface
8 bits, 1 stop bit, even parity,
no handshake, baud rate
9600 bits/s
9−pin sub−D socket
10 m
Pin 2: Received Data (RxD)
Pin 3: Transmitted Data (TxD)
Pin 5: Signal Ground (SGND)
Clean with a soft cloth
Festo SPC200−MMI−1F 0503a English