21"
(53.3 cm)
1-7/8"
(4.8 cm)
3-1/4"
(8.3 cm)
Product Information
With neck jets
Without neck jets
Required accessories:
Jet trim kit
Fixture*:
basin area
Bathing
42" (106.7 cm) x
well
26" (66 cm)
water depth
To
15" (38.1 cm)
overflow
* Approximate measurements for comparison only.
Product
Pump
Neckjets
2 hp
w/o
1.5 hp
Neckjets
* Approximate measurements for comparison only.
Drop-in cut-out
58-1/2" (148.6 cm) x 40-1/2" (102.9 cm)
Included Components:
Cutout template
1019470-1-C
All manuals and user guides at all-guides.com
K-772-N1
8-7/8"
(22.5 cm)
60" (152.4 cm)
2-7/8" (7.3 cm) 1/4" (6 mm)
3" (7.6 cm)
K-772-N1
shown
K-772-N1
not shown
K-9696
top area
weight
54" (137.2 cm) x
460 lbs
32" (81.3 cm)
(208.7
kg)
capacity
70 gal (265 L)
Heater
V
A*
1.5 kW
240
15
1.5 kW
240
11
K-583 template
No change in measurements if connected with drain
illustrated. (K-7161-AF or K-7161M-AF)
Pump/Control Access
34" (86.4 cm) W x 15" (38.1 cm) H
3/4"
(1.9 cm)
20-3/8"
(51.8 cm)
1-1/2" OD
Required Electrical Service
Dedicated circuit required, protected with a Class A
Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage
Circuit-Breaker (ELCB):
Pump/control
208-240 V, 20 A, 50/60 Hz
Locate the outlet behind the whirlpool and within 24"
(61 cm) of the pump.
Installation Notes
Install this product according to the installation guide.
Cast iron whirlpools are extremely heavy, making some drop-in
installations difficult. Splitting the deck/surround is recommended
if installing into a deck.
Floor support under whirlpool must provide for a minimum of
1500 lbs (680.4 kg).
Hot water supply should be 70% of capacity or greater.
Installations will vary.
Fixture conforms to ASME Standard A112.19.1M. All dimensions
are nominal.
2
42" (106.7 cm)
Kohler Co.