7.2.7
ClenCyl
Menu for setting the opening and closing times for the FCV cleaning cycle. The FCV cleaning
cycle is repeated 3 times when filter cleaning is activated for both manual and automatic filter
cleaning. If TH is set to 0, no filter cleaning is performed.
NOTE!
If PSIFC is activated, 'Switch=On', TH cannot be set to 0. See Section '7.3.7 PSIFC'.
The default time for a complete cleaning cycle is 15 seconds. 3(TH+TL)=3*5=15 where
TH=02:00s and TL=03:00s.
TH=02:00s: The default time for the FCV to be open.
TL=03:00s: The default time for the FCV to be closed. The minimum setting is 3 seconds.
Ta=00:00: The elapsed time since the FCV cleaning cycle was activated.
ClenCyl
TH = 02:00s
TL = 03:00s
Ta = 00:00
7.3
Parameter settings: Accessories, customer connections
7.3.1
FlushTmr
Menu for automatic flushing of the duct system with the interval timer. FlushTmr activates
FlushCy1 and FlushCy2. FlushTmr is deactivated if PSCFlush is activated 'Switch=On', see
Section '7.3.8 PSCFlush'.
T=60:00m: Time between flushings. The default setting is 60 minutes.
Ta=00:00: The elapsed time since the flushing cycle started.
FlushTmr
T=60:00m
Ta=00:00
NOTE!
For a description of the following displays please see the 'Installation and service
manual'.
7.3.2
MFDPS-FC
MFDPS-FC
T=01:00m
Ta=00:00
7.3.3
MFDPS-Wr
MFDPS-Wr
T=10:00m
Ta=00:00
TH=
TL=
ESC
OK
T=
ESC
OK
T=
ESC
OK
T=
ESC
OK
FlexPAK 800/1000 DX
EN
43