Stove FOGO, FAYAL, FANTALE
Instruction
Contents
•
Foreword ................................................. Page 8
•
Technical Data ..................................................... 8
•
•
•
•
•
•
Operation ............................................................. 9
•
Cleaning ............................................................. 11
•
Spare parts ......................................................... 11
•
What to do if? .................................................... 11
Foreword
This stove is a top quality modern heating technology
product.
A large degree of user comfort and high fuel utilisa-
tion enable it to be used as high quality space heat-
ing, without having to do without the cosy atmos-
phere of an open fire.
Proper installation and correct handling and care are
indispensable for problem-free operation and a long
service life. Please therefore observe all the informa-
tion given in these instructions. We are convinced
that you will then derive a great deal of pleasure from
this stove.
Please keep these instructions in a safe place so that
you can read through them at the start of each heat-
ing period.
Should you find any transport damage, please report
it to your supplier immediately as otherwise it will not
be possible to correct the damage free of charge.
Technical Data
- Nominal thermal output
- Height to middle of the connector pipe with
the connection is at the back
- Height to top edge of connector pipe with
the connection at the top
- Connection pipe
- max.Weight Fogo/Fantale/Fayal [kg] 159/240/225
- Heigt to middle
of combustion air connection
- Connection combustion air
- Operating Mode
8
GB
[kW]
6,0
[mm]
950
[mm]
1127
∅ 150
[mm]
[mm]
230
∅ 120
[mm]
Intermitting burning
Page 8 - 11
Regulations to be observed
•
Local and building law regulations
•
The stove must be installed by a professional
and connected to the chimney.The specific na-
tional regulations for safe installation of the con-
nector must be complied with.
•
The stove complies with EN 13240.
The heating stove's fire door is self-closing; it is
therefore approved for connection to chimneys with
multiple connections.
It must be ensured that adequate combustion air is
available. If necessary, it must be fed from the out-
side.Please contact your local master chimney
sweep, specialist trader or skilled tradesman for pro-
fessional advice.
Chimney design
The chimney is designed to EN 13384-2 or to the
specific national regulations.
Necessary data
:
Closed operation:
•
Nominal thermal output
•
Waste air mass flow rate
Wood / Brown coal briquette [g/s]
•
Waste air temperature
Wood / Brown coal briquette [°C]
•
Minimum delivery pressure
at nominal thermal output
23/4_6
[kW]
6,0
5,2 / 7,0
360 / 370
[Pa]
12