Operating with hot water/steam
We recommend the following cleaning tem-
peratures:
– Light contaminations
86 °F/30 °C-122 °F/50 °C
– Contaminations containing protein, i.e.
in the food processing industry
max. 140 °F/60 °C
– Vehicle cleaning, machine cleaning
140 °F/60 °C-194 °F/90 °C
– De-preserve, contaminations contain-
ing strong fat contents
212 °F/100 °C-230 °F/110 °C
– De-frosting of surcharge substances,
partially facade cleaning
up to 284 °F/140 °C
Operating with hot water
DANGER
Scalding danger!
Set temperature regulator to desired
temperature.
Operating with steam
DANGER
Scalding danger!
Therefore the following measures must
definitely be performed:
Replace high pressure nozzle (stain-
less steel) with steam nozzle (brass,
order see specification).
Set the working pressure/quantity regu-
lation at the pump unit to the minimum
quantity.
Set temperature regulator to min.
212 °F/100 °C.
Interrupting operation
Secure the trigger gun. To do so, push
the safety catch towards the front.
After operation with detergent
Set dosing value for detergent to "0".
Set the appliance switch to "1" (opera-
tion with cold water).
Open the hand spray gun and rinse the
appliance for at least 1 minute.
All manuals and user guides at all-guides.com
Danger of scalding from hot water! After the
operation with hot water or steam, the de-
vice must be operated with opened gun
with cold water for at least two minutes.
Shut off water supply.
Open the hand spray gun.
Switch on the pump with the power
Close the hand spray gun.
Set the appliance switch to "0/OFF".
Pull main plug out of socket with dry
Remove water connection.
Activate hand spray gun until device is
Secure the trigger gun. To do so, push
Lock in the steel pipe into the holder of
Roll up high pressure hose and electri-
Note: Do not twist high pressure hose and
electrical conduit.
ATTENTION
Risk of damage! Frost will destroy the appli-
ance if the water has not been completely
drained.
Store in a frost free area.
If the device is connected to a chimney, the
following must be observed:
ATTENTION
Threat of damage by penetrating cold air
through the chimney.
Disconnect device from chimney when
If it is not possible to store frost free, shut
down device.
– 8
EN
Turn off the appliance
DANGER
switch and allow to run for about 5-10
seconds.
hands only.
pressure less.
the safety catch towards the front.
Storing the Appliance
the appliance hood.
cal conduit and hang them into the re-
spective holders.
Frost protection
outside temperature drops below 32 °F/
0 °C.
15