Maintenance Works
Clean the sieve in the water connection
Take out sieve.
Clean sieve in water and reinstall.
Cleaning the fine filter
Unpressurize the appliance.
Unscrew the fine filter from the pump
head.
Remove the fine filter and the filter in-
sert.
Clean the filter with clean water or com-
pressed air.
Reinstall in reverse sequence.
Clean sieve in the water shortage safe
guard
Loosen covering nut and take off hose.
Take out sieve.
Note: If necessary turn in screw M8 appr.
0.2 in/5 mm inwards and therewith pull out
sieve.
Clean sieve in water.
Push sieve inwards.
Put on hose.
Tighten covering nut firmly.
Clean filter at the detergent suck hose
Take out detergent suck supports.
Clean filter in water and reinstall.
Oil change
Ready a catch bin for appr. 0.26 gal/
1 Liter oil.
Loosen release screw.
Dispose of old oil ecologically or turn in at
a gathering point.
Tighten release screw.
Fill oil slowly up to the MAX marking.
Note: Air pockets must be able to leak out.
For oil type refer to technical specifica-
tions.
Troubleshooting
DANGER
Risk of injury by inadvertent start-up of ap-
pliance and electric shock. Prior to all work
on the appliance, switch off the appliance
and pull the power plug.
All manuals and user guides at all-guides.com
1x blinking
– Lack of oil
Replenish oil.
2x blinking
– Leak in the high pressure system
Check high pressure system and con-
3x blinking
– Water shortage
Check water supply, check connections.
4x blinking
– Obstructed reed switch in the water
Check water shortage safe guard.
– No line voltage, see "Appliance is not
1x blinking
– Contactor error
Set the appliance switch to "0/OFF".
Turn on the appliance.
– Error occurs repeatedly.
Inform Customer Service.
2x blinking
– Engine overload/overheat
Set the appliance switch to "0/OFF".
Allow device to cool down.
Turn on the appliance.
– Error occurs repeatedly.
Inform Customer Service.
3x blinking
– Fault in the voltage supply.
Check main connections and mains
4x blinking
– Excessive power consumption.
Check main connections and mains
Inform Customer Service.
– 10
EN
Indicator lamp pump
nections for tightness.
shortage safe guard.
Indicator lamp "Ready for use"
turns off
running".
Engine indicator lamp
fuse.
fuse.
17