6
Program overview
Menu 3 Basic settings
Menu
Entry
Selection
item
30
Door setting of upper end position
Reversal of the direction (press for 5 s)
31
Door setting of lower end position
32
Door setting for 1/2 opening position
33
Fine correction of upper end position
50
Factory settings
50 - 0
0...80 mm lower
50 - 99 0...80 mm higher
34
Fine correction of lower end position
50
Factory settings
50 - 0
0...80 mm lower
50 - 99 0...80 mm higher
35
Selection of closing edge safety device
Measurement display (press 5 seconds)
0
Optical closing edge safety device OSE
1
Electrical safety edge 8K2 (default setting)
2
Pressure wave switch with testing
3
Electrical safety edge 8K2 with slack rope
switch
4
Wireless closing edge, RadioBand
36
Selection of photoelectric sensor
0
Without photoelectric sensor (default setting)
1
2-wire photoelectric sensor LS2
2
4-wire photoelectric sensor LS5 photoelectric
reflection sensor
3
Photoelectric sensor LS2, mounted in frame
4
Photoelectric sensor LS5 photoelectric
reflection sensor mounted in frame
5
Light grid with testing (SG14)
37
Correction of pre-limit switch closing edge safety
25
Correction of pre-limit switch closing edge
safety (default setting)
25 - 0
0...50 mm lower
25 - 99 0...100 mm higher
38
Response of photoelectric sensor
0
No reduced open time (default setting)
1
Reduced open time with AR operation
- -
Exit menu
Menu 4 Further door settings
Menu
Entry
Selection
item
40
Selection of operating mode
0
Dead man OPEN / dead man CLOSE
1
Pulse OPEN / dead man CLOSE
2
Pulse OPEN / pulse CLOSE (default setting)
3
AR - automatic closing
41
Response to closing edge safety device
0
Full reversing (default setting)
1
Partial reversing
Menu 4 Further door settings
Menu
Entry
Selection
item
44
Hold-open time in seconds
0
0 s (default setting)
1 - 30
1 s - 30 s (in increments of 1 s)
31 - 60 35 s - 180 s (in increments of 5 s)
61 - 99 190 s - 22.5 min (in increments of 30 s)
45
Status relay X5
0
Door close signal (default setting)
1
Door open signal
2
Status of door for traffic light control A800
3
2-minute garage light
4
5-minute garage light
5
On / off with hand-held transmitter (menu
item 62)
6
ELTACO wipe pulse
46
Status relay X6
0
Door close signal
1
Door open signal (default setting)
2
Status of door for traffic light control A800
3
Locking
4-14
Warning light closing (0 - 10 s warning time)
15-25
Warning light opening and closing (0 s - 10 s)
49
Motor duty cycle
0
Without limitation (default setting)
1
Geared motor 5.24 (25 min / 35 %)
2
Geared motor 5.24 WS (25 min / 30 %)
3
Geared motor 9.15, 9.20, 9.24 (25 min / 60 %)
4
Geared motor 9.24 WS (25 min / 20 %)
5
Geared motor 6.65 DU (10 min / 35 %)
6
Geared motor 14.15 (25 min / 60 %)
- -
Exit menu
Menu 5 Various settings
Menu
Entry
Selection
item
50
Key switch function (J7)
0
Pulse input OPEN/CLOSE (default setting)
1
Inhibit control panel
2
Inhibit external control elements
3
Inhibit control panel and external control
elements
4
Activate control elements for 10 seconds
5
Switch-over to dead man mode for closing
6
Switch-over to 1/2 opening (winter mode)
7
Pulse input OPEN-STOP-CLOSE
8
Pulse input 1/2 OPEN-STOP-CLOSE
9
Automatic closing AR
10
Pulse input for smoke and heat extraction sys-
tem (setting in menu item 55)
11
Pulse input for smoke and heat extraction sys-
tem, inverted (setting in menu item 55)
12
Mutual locking of door
T100 R
EN - 25