CARE AND MAINTENANCE

IMPORTANT: Before doing any work
on the cleaner, discharge the pressure
and disconnect the electricity and water
supplies.
CHECKING THE PUMP OIL LEVEL
Check the oil level periodically. The oil must be
changed for the first time after 50 working hours,
with subsequent changes every 500 hours. SAE
20/30 (750 gr) oil is recommended .
CHECKING THE WATER INTAKE FILTER
(see fig. F)
Inspect and clean the water intake filter on the inta-
ke union periodically. This is important to prevent
fouling which may impair operation of the pump.
CHECKING THE SPRAY ROD NOZZLE
Replace the nozzle when the pressure drops
below the normal values.
DESCALING
The descaling procedure must be carried out periodically
with specific products. The interval depends on the hard-
ness of the water. Pour one litre of product for every 15
litres of water into a drum containing at least 30 litres of
water. Disconnect the gun from the high pressure line and
place its free end in the drum, in order to form a closed cir-
cuit, and draw the solution into the machine for at least 10
minutes. The delivery end of the line should discharge into
a canvas or mesh bag so that the scale removed is not re-
turned to the circuit. Then restore the normal connection
and rinse with plenty of cold water. This operation should
be carried out by our after-sales service, since the descal-
ing product may cause wear of components. Comply with
the regulations in force when disposing of the descaling
agent.

ELECTRIC DIAGRAM

See illustrations, H.
WATER DIAGRAM
See illustrations,G.

TROUBLESHOOTING

Before doing any work on the machine, disconnect the
electricity and water supplies and discharge the pressu-
re. Proceed systematically to identify Faults following
20
the chart below; if you are still unable to eliminate the
problem, call in the Authorized After-Sales Service.
Fault
When switch "ON" the ma-
chine will not start work-
ing
Cause
• Plug not properly inserted in
socket.
• Electric socket is faulty.
• The main voltage is insuffi-
cient.
• The pump is stuck.
• Gauge of extension lead not
sufficient.
Repair
• Fit plug in power socket cor-
rectly.
• Have
checked.
• Have a check made on the suit-
ability of the mains system.
• Turn switch to ON while keep-
ing nozzle trigger pressed; if
problem persists, contact an au-
thorised service centre.
Fault
The motor stops suddenly
Cause
• Thermic safety switch has
tripped due to the overheating.
• Cable extension seems to be
inadequate.
Repair
• Leave motor to cool for a few
minutes. If the problem persists,
contact an authorised service
centre..
The pump doesn't reach
Fault
the necessary pressure
Cause
• Insufficient flow.
• Water inlet filter is clogged.
• Suction/delivery valves are
clogged or worn out.
• Pressure regulator valve set on
minimum.
• The nozzle is worn out.