G/L Adjustment Set Display
1. Horizontal Phase Adjustment
[H Phase: –206 to +49]
Horizontal phase can be adjusted when a genlock
signal is supplied.
2. Subcarrier Phase Coarse Adjustment
[SC Coarse: 1, 2, 3, 4]
Coarse adjustment of subcarrier phase can be made
when a genlock signal is supplied.
3. Subcarrier Phase Fine Adjustment
[SC Fine: –511 to +511]
Fine adjustment of subcarrier phase can be made
when a genlock signal is supplied.
Detail Set Display
1. Detail Level Setting [Detail: OFF, Low, High]
Contour correction quantity can be selected.
Detail settings made using the Horizontal/Vertical
Detail Level HIGH/LOW Setting.
2. Horizontal Detail Level HIGH Setting
[H Detail Level H: L+1 to +63]
3. Vertical Detail Level HIGH Setting
[V Detail Level H: L+1 to +31]
4. Horizontal Detail Level LOW Setting
[H Detail Level L: 0 to H–1]
5. Vertical Detail Level LOW Setting
[V Detail Level L: 0 to H–1]
Detail level can be set in horizontal (H) and vertical
(V) directions with the Detail Level Setting (-1) at
HIGH or LOW.
Whichever the direction, H or V, the set level at HIGH
must be at least one position higher than that at LOW.
6. Detail Band Setting [Detail Band: 1 to 5]
A contour correction band can be set with the Detail
Level Setting (-1) at HIGH or LOW. The higher
setting, the finer will be the detail.
- 62 (E) -