Calibration of sensor and LiqTec
Step
Action
Check that the sensor is correctly connected to the
1
LiqTec, see page 25.
Before fitting the sensor in the pump, submerge the
sensor into stagnant water. Any kind of container with
water can be used.
2
Note: It is important that the water is stagnant as the
calibration will be misleading if the sensor is cooled by
flowing water.
Keep the buttons, pos. 6 and 12, pressed for approx.
3
20 seconds.
When the green indicator lights, pos. 3 and 9, are
4
permanently on, stop pressing the buttons, pos. 6
and 12.
Further information
Information related to IEC 60 730-1:
• Software class A.
• Pollution degree 2.
• Type 1.
The LiqTec has been cURus approved according to
UL 508.
Maximum pressure:
Maximum liquid temperature:
Maximum ambient temperature: +55°C.
Power consumption:
Enclosure class:
Maximum cable length:
Standard cable:
Extension cable:
Product number:
All manuals and user guides at all-guides.com
40 bar.
+130°C ±5°C.
5 Watt.
IP X0.
20 metres.
5 metres.
15 metres.
96443676.
Result
All red indicator lights (except pos. 7)
start flashing.
The calibration is completed.
Disposal
Disposal of this product or parts of it must be carried
out according to the following guidelines:
1.
Use the local public or private waste collection
service.
2.
In case such waste collection service does not
exist or cannot handle the materials used in the
product, please deliver the product or any haz-
ardous materials from it to your nearest Grund-
fos company or service workshop.
Subject to alterations.
5