BGS technic 70106 Instruction Manual página 15

Calentador de inducción manual
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

THE FUNCTION OF EACH CONNECTOR PIN REMOTE CONTROL
Pin Designation Function
1
GND
2
INC
3
OK
4
485A
5
VOUT
6
INV
7
ON
8
RUN
9
485B
TRANSMISSION TABLE OF ANALOG CONTROL
Power
Interval INV
(%)
10
20
30
40
50
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Type
Common grounds of
GND
signals and power
0-20 mA, 4-20 mA
Input
Current loop
Rin = 160 Ω
Open collector
Output
maximum
24 V/100 mA
Reserved
Input
(differential RS485
Output
digital line)
12 V, 100 mA
Power
max. power
external circuitry
Analog input 0-10 V
Input
Rin = 10k Ω
Negativ digital input
Input
with „pull-up"
resistor
Open collector
Output
max. 24 V/100mA
Reserved
Input
(differential RS485
Output
digital line)
Interval INC
(V)
(mA)
0-1
0-5,6
1-2
5,6-7,2
2-3
7,2-8,8
3-4
8,8-10,4
4-5
104,-12
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
6
Description
Output power port for control
circuits and accessories
Analog input that determines the
output power of the unit
at a range of 10-100% in steps of 10%
according to the conversion table Page 6
Digital output function:
Low impedance ->> the device is OK and ready
High impedance ->> error or initialization
Output power port for control
circuits and accessories
Analog input that determines the output power
of the unit at a range of 10-100% in steps
of 10% according to the conversion table
Digital input with function:
Low impedance ->> closed output
High impedance ->> off output
Digital ouput function feedback:
Low impedance ->> closed output
High impedance ->> off output /
Power
Interval INV
(%)
(V)
60
5-6
70
6-7
80
7-8
90
8
100
9-10
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed
state apparatus
Page 6
error or initialization
state apparatus
Interval
(INC)
12-13,6
13,6-15,2
15,2-16,8
16,8-18,4
18,4-20