INTERNAL CONNECTION OF REMOTE CONTROL
WARNING!!!
Attention, the remote control circuits are not galvanically isolated from the induction heater secondary
control circuits. For this reason, it is necessary to use optoelectrons, relays or galvanically isolated
transducers in accordance with IEC 60071-1 and IEC 60664-1 when connecting a parent system!
The manufacturer reserves the right to terminate the warranty period, if damage occurs due to
improper or improper connection of the remote connection circuits.
PROTECTION
Protection type
Short-circuit protection and overcurrent output
Overheat protection
Protection against overheating accesories
Protection against tripping in the event
of a protective conductor discontinuity
Protection against non-standard
conditions of operation at the mains
LIST OF ERRORS MESSAGE
Error message
1
2
3
4
5
6
7
>15
REPLACING HEATING INDUCTOR
Before connecting any accessories carefully check its status. In any case, do not connect it to the
device in the event of any damage to the accessory.
The heating inductor is easily connectable by means of an unmistakable connector.
Always make sure that the connector is properly secured by a latch when attaching the accessories,
as only when the connector is secured, the contacts are securely connected.
Do not change the inductor in any case with the appliance switched on.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Undervoltage
Overvoltage
Output current
Network synchronization failure
Overheating accesories
Overheat device
Fan stop
Service error device
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
7
Parameters
24 A < 200 ns
Max. 80°C on the inverter cooler
Max. 65°C process of coil winding
or impedance transformer
with detection of a protective
wire extension process
Voltage 195-265 V
Frequency 46-65 Hz
Error description
www.bgstechnic.com