Description
Below is a list of the contents of the package delivered to the
customer. If one of the parts listed below is missing, contact the
dealer immediately. To avoid loss during transport, the key is
enclosed in the bag with the technical documents.
1 machine
1 high pressure hose with M22 connectors
1 handgrip
1 wand with nozzle
1 quick coupling
1 key mm 4
1 Electr. Plug
1 use and maintenance manual
1 spare parts booklet
6

Operator instructions

6.1
Safety warnings
IMPORTANT - Failure to observe the following safety
rules may cause injury or damage to equipment.
6.1.1
Checks to be performed before starting up the
machine.
Before using the machine, make sure all safety
devices are positioned correctly and are in good
condition.
6.2
Prohibited operations
Adjustment, maintenance and/or lubrication may not
be performed with the machine on.
6.3
Training
All users must be suitably trained, including with hands-on
experience of the machine. This training should emphasise:
The need for attention and concentration while working;
Children and unfit persons must not use the machine.
Hold the trigger and wand firmly
Do not use the machine on uneven surfaces
Do not direct the jet at animals or persons
Do not direct the jet towards live parts
Do not unplug the power plug by pulling the cable
Do not use electrical extensions
Do not use the machine with faulty guards
7 Using the high pressure washer

7.1 Water connection

Connect the machine to the mains water supply using a hose
with a diameter of not less than 1/2" (use the quick coupling
provided). Connect the high pressure hose to the machine
and the wand by screwing up the M22 diameter screw
couplings tightly. Mount the nozzle on the wand terminal and
the wand terminal on the trigger.

7.2 Electrical connection

Mount the plug on the cable (use the plug provided or a plug
compatible with the power line). Plug into the power socket,
making sure the main switch on the machine and power line
are both in the OFF position.
Important: check that the power supply voltage and
frequency required by the machine correspond to those of the
power line (check the machine rating plate).
Important: the power socket must be protected by a
differential
circuit-breaker
regulations and standards.
7.3 Electrical boards
The electrical board in the Super model has the panel shown
in the following figure, with:
magnetothermic switch (general)
Boiler thermostat.
Detergent tap
Water pressure gauge
The electrical board in the Super Plus model has the panel
shown in the following figure, with:
in