magnetothermic switch (general)
Boiler thermostat.
Detergent tap
Water pressure gauge
Indicator light panel
The indicator light panel includes the following lights (from
top):
Ready
No flame
No water
No diesel
No water softener
The procedures for starting and resetting the appliance are
described in chapter...
7.4 Tanks
Fill the tanks with the respective products: diesel (main filler),
detergent (small filler) and, in the SUPER PLUS model, water
softener through the filler under the object compartment lid on
the cowling. Each tank has an identification label near the
corresponding filler.
7.5 Start up
Open the mains water tap.
Turn the main switch on. In the SUPER PLUS model, the OK
light comes on to confirm that the machine is powered
correctly.
Hold the wand firmly and turn the main switch on the
appliance to the ON position.
Press the lever on the handgrip a number of times to eliminate
the air present in the circuit. When the jet is constant, set the
thermostat to the required temperature.
boiler is turned on, it may give off a little smoke caused by the
presence of air in the circuit.
Before turning the machine off, set the thermostat to OFF,
wait until the water has cooled down completely (1 or 2
minutes), then turn the main switch off.
7.6 Work method
Super and Super Plus series high pressure washers are fitted
with a Delayed Total-Stop control which shuts the machine
down a few seconds after the trigger has been released.
When the trigger is pressed again, the machine starts up
normally.
The high pressure washer has a "micro-leak control" function
which shuts the machine down after repeated start-ups
caused by dripping (leaks). If this function trips, the machine
stops. To start it again, turn the main switch to OFF, then back
to ON (reset).
The high pressure washer is fitted with a "no use" function
which shuts the machine down after 20 minutes of inactivity.
If this function trips, the machine stops. To start it again, turn
the main switch to OFF, then back to ON (reset). This function
can be cut out, but the operation must be performed by a
qualified professional.
7.7 Pressure regulation valve
The pressure regulation valve enables water pressure to be
reduced to a maximum of about 25 bars. When this value is
decreased, the valve reduces the quantity of water to be
heated, allowing the temperature to be increased.
function enables water at temperatures of more than 100°C to
be delivered for short periods (value varies according to
model and flow rate).
Important: with such high temperatures, great care must
be taken when manipulating the jet.
Important: prolonged use of high temperatures leads to a
rapid accumulation of limescale.
7.8 Washing with detergent
Open the tap on the panel and operate the lever on the
trigger. The pump automatically takes up detergent from the
tank. Spray the surface to be treated, release the lever on the
trigger, then close the detergent tap. Operate the lever on the
trigger again to begin rinsing. N.B.: detergent delivery will
The first time the
This