Maintenance And Care - Winkhaus panicLock AP4 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Installation, Operating and
Maintenance Instructions

4 Maintenance and Care

• Maintenance tests, function checks and checks for the smooth running of the
door lock should be performed by the operator or an authorized person at
least once a month!
• Maintenance, care and cleaning of the cylinder are to be carried out
according to the guidance of the cylinder manufacturer.
• Components of the door furniture relevant to security have to be checked
for tight-ness and wear at regular intervals. If required, the retaining screws
should be re-tightened and any defective parts should be replaced.
• You should only use neutral cleaning agents or care products that do not
contain any abrasives to protect the anticorrosion coating of the door
furniture.
• Check! The emergency exit / panic locking system must be lubricated once a
year, or up all 20,000 operating cycles at least, if necessary more often
(e.g. Automatic locking system).
Recommended greases:
a) Klüber, Klüberelectric KR 44-22
b) Divinol, Profilube SL
c) Divinol F14 EP
d) Shell Gadus S2 V100
(T-POLFETT 10 GR STÖßEL item no. 5040239)
• It must be checked regularly to see if the operating element is properly fixed.
The force necessary to open the escape door lock must be measured with
a force meter. The measured values have to be compared with the values
measured after the first installation to see if there are major changes.
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49  369  3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
panicLock AP4
51
5062179
EN
4

Publicidad

Tabla de contenido
loading

Tabla de contenido