12. Troubleshooting guide
The table below contains a list of fault symptoms and explains what you can do to remedy the problem
if your equipment fails to work properly. If the problem still persists after working through the list, please
contact your nearest service workshop.
Fault
The equipment
- Correct starting procedure not follo-
does not start
wed
- Sooted or damp spark plug
- Incorrect carburetor setting
The equipment
- Incorrect choke lever setting
starts but does
- Soiled air fi lter
not develop its full
- Incorrect carburetor setting
power
The engine does
- Incorrect electrode gap on the
not run smoothly
spark plug
- Incorrect carburetor setting
Engine smokes ex-
- Incorrect fuel mix
cessively
- Incorrect carburetor setting
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers
accompanying products is permitted only with the express consent of the iSC GmbH.
Subject to technical changes
Anl_GH_BC_43_AS_SPK7.indb 29
Anl_GH_BC_43_AS_SPK7.indb 29
GB
Possible cause
- Follow the instructions for starting
- Clean the spark plug or replace it
with a new one
- Contact an authorized customer
service outlet or send the equip-
ment to ISC GmbH
- Set the choke lever to „ "
- Clean the air fi lter
- Contact an authorized customer
service outlet or send the equip-
ment to ISC GmbH
- Clean the spark plug and adjust the
electrode gap, or fi t a new spark
plug
- Contact an authorized customer
service outlet or send the equip-
ment to ISC GmbH
- Use the correct fuel mix (see fuel
mixing table)
- Contact an authorized customer
service outlet or send the equip-
ment to ISC GmbH
- 29 -
Remedy
13.11.14 16:31