Installation must be performed by qualified technicians according to the law in force.
WARNINGS:
Should the unit be installed against a wall, the latter must be heat-resistant to temperatures of 100°C and must be fireproof;
on the contrary it is necessary the application of a thermic insulation.
Before proceeding with the installation, remove the protective plastic film from the relevant parts, eliminating any adhesive
residues with an appropriate cleaning product suitable for stainless steel.
Install the unit in a horizontal position; its correct levelling will be achieved by rotating the adjustable feet.
The equipment can be separately installed or joined to other equipment belonging to the same range MINIMA.
This equipment is not suitable for embedding.
3.2

INFORMATION ABOUT GLASS-CERAMIC RANGES MINIMA SERIES

The plate with technical data is located on the back of the equipment and in the present manual it is reproduced on page 6.
3.3

LAWS, REGULATIONS AND TECHNICAL DIRECTIVES

The following indications should be observed during installation:
- Accident and fire regulations in force
- The regulations of the electric power supply company.
- Hygienic regulations.
- The rules for electrical systems.
3.4

ELECTRICAL CONNECTION

Electrical connection should be performed in compliance with the IEC regulations, only by authorised and competent personnel.
In the first instance, examine the data shown on the technical data table of this manual, on the label and on the electrical diagram.
The envisaged connection is of the fixed type.
IMPORTANT: Ahead of each unit it is necessary to install an omnipolar main breaker, having a spacing among contacts of at
least 3mm; example:
- manual breaker of appropriate capacity, complete with fuse valves
- automatic breaker with respective magnetothermal relays.
3.4.1

EARTHING

It is essential to earth the unit.
To this purpose, it is necessary to connect to an efficient earthing system the terminals marked with the symbols (
on the line-receiving terminal box. The earthing system should comply with the law in force.
The Manufacturer cannot be deemed responsible for any damages caused by the lack of unit earthing.
ATTENTION: NEVER INTERRUPT THE EARTH WIRE (Yellow-Green).
3.4.2

EQUIPOTENTIAL

The unit should be included within an equipotential system whose efficiency must be tested according to the law in force. The
screw marked with the label "Equipotential" is located at the back.
3.4.3

POWER SUPPLY CABLE

The unit is supplied fitted for the following voltages: 3N AC 380...415V; 2 AC 380...415V; 3AC 220...240V; 1N AC 220...240V
50/60 Hz.
The flexible cable for power supply connection should not have characteristics lower than the rubber insulation type H07RN-F. The
cable should be inserted through the cable clamp and firmly fastened. Furthermore, the supply voltage with the unit functioning
should not go outside the value of the nominal tension ±10%.
The equipment is equipped with a cable as per specifications of table 3 (page 8); in order to replace it or reach the terminal board
it is necessary to
- remove the frontal panel;
- connect the cable to the terminal box according to need, and following the instructions shown on the provided sticker near the
terminal bord and on the present booklet.