Electrical Connection; Earthing; Equipotential; Power Supply Cable - MBM MINIMA Serie Instrucciones Para La Instalación, El Uso Y El Mantenimiento

Baños maria eléctricos
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

2.3

ELECTRICAL CONNECTION

Electrical connection should be performed in compliance with the IEC regulations, only by authorised and competent
personnel. In the first instance, examine the data shown on the technical data table of this manual, on the serial plate and on
the electrical diagram.
The envisaged connection is of the fixed type.
IMPORTANT: Ahead of each unit it is necessary to install an omnipolar main breaker, having a spacing among
contacts of at least 3mm; example:
- manual breaker of appropriate capacity, complete with fuse valves
- automatic breaker with respective magnetothermal relays..
2.3.1

EARTHING

It is essential to earth the unit.
To this purpose, it is necessary to connect to an efficient earthing system the terminals marked with the symbols (
placed on the line-receiving terminal box. The earthing system should comply with the law in force.
The Manufacturer cannot be deemed responsible for any damages caused by the lack of unit earthing.
ATTENTION: NEVER INTERRUPT THE EARTH WIRE (Yellow-Green).
2.3.2

EQUIPOTENTIAL

The unit should be included within an equipotential system whose efficiency must be tested according to the law in
force. The screw marked with the label "Equipotential" is located on the back.
2.3.3

POWER SUPPLY CABLE

The unit is supplied fitted for the following voltages: 1N AC 220...240V 50/60 Hz.
The flexible cable for power supply connection should not have characteristics lower than the rubber insulation type
H07RN-F. The cable should be inserted through the cable clamp and firmly fastened. Furthermore, the supply voltage
with the unit functioning should not go outside the value of the nominal tension ±10%.
This equipment is provided with a cable having the characteristics specified in Table 3 (page 8); to have access to the
terminal board or to replace it, proceed as follows:
- remove the front panel
- connect the cable to the terminal box according to need, and following the instructions shown on the provided label near
the terminal bord and on the present booklet.
2.3.4

CONNECTIONS TO VARIOUS MAIN POWER SUPPLIES

1N AC 220...240 V 50/60 Hz
CABLE DE ALIMENTACIÓN
TYPE OF TENSION
1N AC 220...240 V 50/60 Hz
GB
MODEL
EBM46
Max.
N° cables
2
A/f
mm
6,4
3 x 1,5
- 10 -
PE (earth)
yellow-gree
N
(NP)
blue
L
(R)
brown
1
EBM66
Max.
N° cables
2
A/f
mm
12,8
3 x 1,5
)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

BagnomariaEbm46Ebm6Ebm66

Tabla de contenido