Dräger Polytron ® Repeater Isa; Sensors; Interfaces; Intended Use - Dräger Polytron 6100 EC WL Instrucciones De Uso

Ocultar thumbs Ver también para Polytron 6100 EC WL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 80
Alarms
The alarms configured in the gas detector are not transmitted via the ISA100
Wireless process interface. Alarms are output only via the red LED. They are
purely informative and are used to locate an alarming device and are not
intended for the derivation of a safety task or action. The alarms are non-
latching. When alarm conditions are resolved, the alarm is no longer displayed.
If alarm logic is used for countermeasures, implement alarm logic in the
controller.
Maintenance
In potentially explosive gas atmospheres, the gas detector can be serviced
without declassifying the area.
WARNING
Risk of explosion!
If the gas detector is opened in a potentially explosive dust atmosphere, an
explosion may occur.
► Do not open the gas detector in dust explosion-hazard areas. Alternatively,
declassify the dust explosion-hazard area beforehand.
®
3.2.2
Dräger Polytron
Repeater ISA
®
The Dräger Polytron
Repeater ISA is a version of the Dräger Polytron
EC WLwithout measuring function.
3.3

Sensors

The gas detector is intended for use with the DrägerSensor
(electrochemical). Select the sensor according to the target gas to be
measured.
3.4

Interfaces

Interface
ISA100 Wireless
network
Instructions for use
|
Dräger Polytron
®
EC
Connection via the network (see "Network
integration", page 41).
®
6100 EC WL, Dräger Polytron
Interface
®
Bluetooth
3.5

Intended use

3.5.1
Dräger Polytron
The gas detector is used in conjunction with the built-in DrägerSensor
monitoring toxic gases and oxygen.
3.5.2
Dräger Polytron
The repeater is used to relay data from other ISA100 Wireless ™ network
subscribers.
3.6

Approvals

The approvals are shown on the name plate. A copy of the name plate and the
declaration of conformity can be found in the document "Notes on Approval"
®
6100
(order no. 93 00 060).
4

Operation

If the product is operated by a battery, do not remove the battery box during
configuration.
®
Repeater ISA
Operation
Connection to a Windows mobile device in
the field (see "Activating the Bluetooth
interface", page 36).
®
6100 EC WL
®
Repeater ISA
|
en
®
®
for
35

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Polytron repeater isa

Tabla de contenido