12
TECHNICAL DATA
12
Technical data
Sensing range max.
Light spot size / distance
Supply voltage U
B
Ripple
Current consumption
Output current I
max.
Max. response time
Switching frequency
Enclosure rating
6)
Protection class
en
Circuit protection
Ambient temperature, operation
1)
Background with 6%
16 VDC to 30 VDC, without load
2)
3)
10 VDC to 16 VDC, without load
4)
Signal transit time with resistive load in switching mode. Deviating values possible in COM2 mode.
5)
With a light/dark ratio of 1:1 in switching mode. Deviating values possible in IO-Link mode.
6)
Pursuant to EN 60529
7)
Replaces IP69 K pursuant to ISO 20653: 2013-03
8)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
9)
Do not bend cables below 0°C.
12.1
Dimensional drawings
32
O P E R A T I N G I N S T R U C T I O N S | WTF16
WTF16P-xxxxx2,
WTF16P-xxxxx6
0 mm ... 400 mm (type)
Ø 3 mm (200 mm) (type), Ø 6 mm
(500 mm) (type)
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
2)
< 50 mA
3)
≤ 100 mA
500 µs
4)
1,000 Hz
5)
see table
0:
x4, xH, x5, xI: IP66, IP67, IP69
III
A, B, C, D
8)
-40 °C ... +60 °C
42
20
4.1
(0.79)
(0.16)
2
29.9
7.8
1
(0.31)
35.5
3
4
5
Ø 12.9
7.7
27.8
(0.51)
(0.3)
Figure 11: , cable
Preferred direction of the target
1
object
Center of optical axis, sender
2
Center of optical axis, receiver
3
Fixing hole, Ø4.1 mm
4
Connection
5
Display and setting elements
6
WTF16P-xxxxx4
0 mm ... 600 mm
1)
Ø 6 mm (500 mm)
DC 10 ... 30 V
≤ 5 V
≤ 30 mA
< 50 mA
≤ 100 mA
2.5 ms
200 Hz
see table
x4, xH, x5, xI: IP66, IP67, IP69
7)
III
A, B, C, D
9)
-40 °C ... +60 °C
(1.65)
20
(0.79)
6
2
(0.18)
1
(1.4)
6
3
(0.24)
6.5
(0.26)
3
(0.12)
15
(0.59)
M12
(1.09)
Figure 12: , male connector
1)
SS
2)
3)
4)
5)
0:
7)
8)
9)
42
(1.65)
4.1
(0.16)
6
29.9
(0.18)
52.9
(2.08)
17.5
6
(0.24)
(0.24)
4
5
3
(0.12)
15
7.5
(0.3)
28
(1.1)
35.5
(1.4)
8024126.1DS6/2021-11-24 | SICK
Subject to change without notice
6.5
(0.26)
(0.59)