WARNING: Only use hydraulic cylinders in a coupled
system. Never use a cylinder with unconnected couplers.
If the cylinder becomes extremely overloaded, components
can fail catastrophically causing severe personal injury.
IMPORTANT: Hydraulic equipment must only be serviced
by a qualified hydraulic technician. For repair service,
contact the Authorized ENERPAC Service Center in your
area. To protect your warranty, use only ENERPAC oil.
WARNING: Immediately replace worn or damaged parts
with genuine ENERPAC parts. Standard grade parts will
break causing personal injury and property damage.
ENERPAC parts are designed to fit properly and withstand high loads.
3.0 SPECIFICATIONS
Operating Pressure
Electric Power Source
Motor Type and Rating
Flow Rate
Max. Operating Temperature
Pump Model
WUD-1100B/E
WUD-1101B/E
WUD-1300B/E
WUD-1301B/E
C
D
Pump Model
WUD-1100B/E, WUD-1300B/E
WUD-1101B/E, WUD-1301B/E
Pump models ending in "B"
15 Amps, 120 Volts, grounded, 1 Phase, 50/60 Hz
1/2 HP Universal, 9 Amps at 5,000 psi [350 bar]
{35 mPa} and 12,000 RPM.
Operates at 60-125 Volts, 85-89 dBA
200 in.
Used With
Single-Acting Cylinders
Single-Acting Cylinders
F
A
Figure 1, External Dimensions
A
B
9.8
9.62
[249]
[244]
14.50
12.18
[368]
[309]
CAUTION: Check specifications and motor plate data.
Use of an incorrect power source will damage the motor.
WARNING: ELECTRIC SHOCK HAZARD: Line voltage
is present inside the pump even when the pump shroud
switch is in the "OFF" position. To prevent electric shock,
always unplug power cord from outlet before removing pump
shroud or performing any other maintenance or repairs. All
servicing must be done by qualified personnel.
0-5,000 psi [350 bar] {35 mPa}
/min. [3,3 l/min] at 0-200 psi [0-14 bar] {0-1,4 mPa}
3
25 in.
/min. [0,4 l/min] at 5,000 psi [350 bar] {35 mPa}
3
150°F [65°C]
Valve Type
Dump
Dump/Hold
Outlet Port
SAE #4
Tank Port
³/
" – 18
8
NPTF
E
Dimensions in inches [mm] (Refer to Figure 1)
C
D
14.25
4.00
[362]
[101]
14.72
4.15
[373]
[105]
2
Pump models ending in "E"
10 Amps, 220 Volts, grounded, 1 Phase, 50/60 Hz
0.37 kW Universal, 4.5 Amps at 5,000 psi [350 bar]
{35 mPa} and 12,000 RPM.
85-89 dBA
Usable Oil Capacity
0.5 Gal. [1,9 l]
1.0 Gal. [3,8 l]
0.5 Gal. [1,9 l]
1.0 Gal. [3,8 l]
H
J
B
E
F
6.75
8.00
[172]
[203]
7.20
12.74
[183]
[323]
Weight
31 lbs. [14,0 Kg]
43 lbs. [19,5 Kg]
31 lbs. [14,0 Kg]
43 lbs. [19,5 Kg]
H
J
0.40
5.25
[10,1]
[133]
0.40
6.56
[10,1]
[167]